KAPA HyperPrep Kits

Overview

KAPA HyperPrep Kits offer a streamlined library preparation protocol that combines several enzymatic steps and eliminates bead cleanups to significantly reduce library preparation time and improve consistency. The novel, single-tube chemistry offers further improvements to library construction efficiency, particularly for challenging samples such as FFPE and cell-free DNA. KAPA HyperPrep Kits offer complete library preparation solution with KAPA Adapters and KAPA Pure Beads.

Features and Benefits of KAPA HyperPrep Kits
  • Robust and reproducible library construction in 2-3 hours with high conversion rates and library complexity, particularly for FFPE
  • PCR-free workflows from lower sample inputs and improved sequence coverage for workflows with PCR
  • Compatibility with a wide range of sample types and inputs, and flexibility with respect to fragment size, adapter design and library amplification
  • Qualified automation methods
  • Validated with the HyperCap Workflow v2.0
Product Highlights

Improved library yields and quality

  • Higher library yields translating to greater molecular complexity
  • Higher conversion of input DNA to adapter-ligated library
  • Fewer cycles of amplification with KAPA HiFi DNA Polymerase, resulting in lower duplication rates and improved coverage

Minimal amplification bias

  • Kits with or without an amplification module
  • Lower PCR bias resulting in more uniform coverage in PCR workflows

High coverage of FFPE samples

  • Higher library yield, higher library complexity and fewer PCR cycles
  • Lower duplication rates and higher coverage

Improved performance with cell-free DNA

  • Ability to optimize adapter:insert ratios for challenging sample types, such as cell-free DNA
  • Higher library density compared to competitor kit*
  • Comparable duplication rates to vendor kits specific for low-input applications

*Data on file.

For Research Use Only. Not for use in diagnostic procedures.
KAPA and SEQCAP are trademarks of Roche. All other product names and trademarks are the property of their respective owners.

Specifications
Spec
Description
Compatible Platform All Illumina sequencing instruments
Library Type
DNA
Starting Material
Fragmented DNA, cDNA, PCR amplicons
Input Amount
-15°C to -25°C

Kits can be stored at -20˚C.

Kits contain KAPA End Repair & A-Tailing Buffer, KAPA End Repair & A-Tailing Enzyme, KAPA Ligation Buffer, KAPA DNA Ligase, KAPA HiFi HotStart ReadyMix and KAPA Library Amplification Primer Mix

For Research Use Only. Not for use in diagnostic procedures.
KAPA and SEQCAP are trademarks of Roche. All other product names and trademarks are the property of their respective owners.

For Research Use Only. Not for use in diagnostic procedures.
KAPA and SEQCAP are trademarks of Roche. All other product names and trademarks are the property of their respective owners.

Kit Code Roche Cat. No
Description
Kit Size (reactions)
How to buy
KK8501 07962339001
KAPA HyperPrep Kit (PCR-free) 8 Contact Us
KK8503
07962355001
KAPA HyperPrep Kit (PCR-free)
24 Contact Us
KK8505
07962371001
KAPA HyperPrep Kit (PCR-free)
96 Contact Us
KK8500
07962312001
KAPA HyperPrep Kit 
8 Contact Us
KK8502
07962347001
KAPA HyperPrep Kit 
24 Contact Us
KK8504
07962363001
KAPA HyperPrep Kit 
96 Contact Us

Accessory Products

All KAPA Adapter Kits contain KAPA Adapter Dilution Buffer and three additional sealing films to support multiple use. KAPA Adapter Dilution Buffer (08278539001) is also available separately, if required.

Kit Code Roche Cat. No
Description
Kit Size 
How to buy
KK8007
08963835001
KAPA HyperPure Beads (5 mL)
5 mL Contact Us
KK8008
08963843001
KAPA HyperPure Beads (30 mL)
30 mL
Contact Us
KK8009
08963851001
KAPA HyperPure Beads (60 mL) 60 mL
Contact Us
KK8011 08963878001 KAPA HyperPure Beads (4 x 60 mL)
4 x 60 mL Contact Us
KK8010
08963860001
KAPA HyperPure Beads (450 mL) 450 mL Contact Us
KK8727
08861919702 KAPA Unique Dual-Indexed Adapters Kit (15μM)
96 adapters x 20 μL each Contact Us
KK8722 08278555702 KAPA Dual-Indexed Adapter Kit (15μM) 96 adapters x 20 μL each Contact Us
KK8721 08278539001 KAPA Adapter Dilution Buffer (25 mL) 25 mL Contact Us

For Research Use Only. Not for use in diagnostic procedures.
KAPA and SEQCAP are trademarks of Roche. All other product names and trademarks are the property of their respective owners.

  • Whole-genome shotgun sequencing
  • Whole-exome or targeting sequencing, using SeqCap® EZ, Agilent SureSelect, IlluminaTruSeq, or IDT xGen® Lockdown® Probes, or other hybridization capture systems 
  • Amplicon sequencing
  • ChIP-seq
  • RNA-seq
  • Methyl-seq (in combination with the KAPA HiFi Uracil+ Library Amplification ReadyMix)

The library construction process, from end repair and A-tailing to final, amplified library, can be performed in less than 3 hours, depending on experience and the number of samples being processed. If necessary, the protocol may be safely paused after completion of the post-ligation cleanup, or prior to post-amplification cleanup.  

Purified, adapter-ligated library DNA may be stored at 2°C to 8°C for 1 – 2 weeks, or at -15°C to -25°C for ≤1 month before amplification, target capture and/or sequencing. To avoid degradation, always store DNA in a buffered solution (10 mM Tris-HCl, pH 8.0 – 8.5) when possible, and minimize the number of freeze-thaw cycles.

 

  • End repair and A-tailing, which produces end-repaired, 5′-phosphorylated, 3′-dA-tailed, dsDNA fragments
  • Adapter ligation, during which dsDNA adapters with 3′-dTMP overhangs are ligated to 3′-dA-tailed library fragments
  • Library amplification (optional), which employs high-fidelity, low-bias PCR to amplify library fragments carrying appropriate adapter sequences on both ends

The library construction process, from end repair and A-tailing to final, amplified library, can be performed in less than 3 hours, depending on experience and the number of samples being processed. If necessary, the protocol may be safely paused after completion of the post-ligation cleanup, or prior to post-amplification cleanup.

Purified, adapter-ligated library DNA may be stored at 2°C to 8°C for 1 – 2 weeks, or at -15°C to -25°C for ≤1 month before amplification, target capture and/or sequencing. To avoid degradation, always store DNA in a buffered solution (10 mM Tris-HCl, pH 8.0 – 8.5) when possible, and minimize the number of freeze-thaw cycles.

  • If you are performing a cleanup between shearing and end repair, shear in 10 mM Tris-HCl (pH 8 or 8.5) + 1 mM EDTA.
  • If you are not performing a cleanup between shearing and end repair, shear in 10 mM Tris-HCl (pH 8 or 8.5) + 0.1 mM EDTA.
  • Never shear DNA in water.

KAPA Adapters are recommended for use with the KAPA HyperPrep Kits. However, the kit is also compatible with other full-length adapter designs wherein both the sequencing and cluster generation sequences are added during the ligation step, such as those routinely used in SeqCap EZ, TruSeq (Illumina) and SureSelect XT2 (Agilent) kits, and other similar library construction workflows. Custom adapters that are of similar design and are compatible with “TA-ligation” of dsDNA may also be used, remembering that custom adapter designs may impact library construction efficiency.

For assistance with adapter compatibility and ordering, please contact Technical Support at www.sequencing.roche.com/support for guidelines on the formulation of user-supplied library amplification primers. 

Ligation efficiency is robust for adapter-insert molar ratios from 10:1 to >200:1. The recommended adapter concentrations for different inputs are given in the table below. Note that high adapter-insert molar ratios are beneficial for low-input and challenging samples. When optimizing workflows for DNA inputs ≤25 ng, it is recommended that two or three adapter concentrations be evaluated. Try the recommended concentration in the table, as well as one or two additional concentrations in the range that is 2 – 10 times higher.

KAPA Adapters may be used for all inputs with the appropriate dilution. For assistance with adapter compatibility and ordering, please visit www.sequencing.roche.com/support.

 

Input DNA Adapter stock concentration Adapter:insert
molar ratio
1 μg 15 μM 10:1
500 ng 15 μM 20:1
250 ng 15 μM 40:1
100 ng 15 μM 100:1
50 ng 15 μM 200:1
25 ng 7.5 μM 200:1
10 ng 3 μM 200:1
5 ng 1.5 μM 200:1
2.5 ng 750 nM 200:1
1 ng 300 nM 200:1

 

High Concentration (30 µM) KAPA Adapter Kits are recommended for library construction from 5 ng – 1 µg inputs, whereas Low Concentration (1.5 µM) KAPA Adapter Kits are recommended for inputs <5 ng. For assistance with adapter compatibility and ordering, please visit sequencing.roche.com/contactus.html

Please refer to the KAPA Adapter Technical Data Sheets for information about barcode sequences, pooling, kit configurations, formulation, and dilution for different KAPA DNA and RNA library preparation kits and inputs.

KAPA Adapters undergo extensive qPCR- and sequencing-based functional and QC testing to confirm:

  • optimal library construction efficiency
  •  minimal levels of adapter-dimer formation
  • nominal levels of barcode cross-contamination

Library construction efficiency and adapter-dimer formation are assessed in a low-input library construction workflow. The conversion rate achieved in the assay indicates library construction efficiency. This is calculated by measuring the yield of adapter-ligated library (before any amplification) by qPCR (using the KAPA Library Quantification Kit), and expressing this as a % of input DNA. To assess adapter-dimer formation, a modified library construction protocol— designed to measure adapter dimer with high sensitivity—is used.

Barcode cross-contamination is assessed by sequencing. Each adapter is ligated to a unique, synthetic insert of known sequence, using a standard library construction protocol

If cycled to completion (not recommended) a single 50 µL KAPA HiFi library amplification reaction can produce 8–10 µg of amplified library. To minimize over-amplification and associated undesired artefacts, the number of amplification cycles should be tailored to produce the optimal amount of amplified library required for downstream processes. This is typically in the range of 250 ng – 1.5 µg of final, amplified library.

Quantification of adapter-ligated libraries prior to library amplification can greatly facilitate the optimization of library amplification parameters, particularly when a library construction workflow is first established or optimized. The amount of template DNA (adapter-ligated molecules) available for library amplification may be determined using the KAPA Library Quantification Kit. A simple algorithm can subsequently be used to theoretically predict the number of amplification cycles needed to achieve a specific yield of amplified library. A calculator that can be used for purpose is available on request from support.

The estimated number of amplification cycles for libraries prepared from different amounts of input DNA is given in the table below. The actual optimal number of amplification cycles may be 1–3 cycles higher or lower, depending on the sample type and size distribution of the input DNA.

If the amount of adapter-ligated library retrieved after the post-ligation cleanup is sufficient for the next process (e.g. direct sequencing), and the library molecules contain all the adapter motifs needed for that process, library amplification may be omitted. This further streamlines the workflow and reduces the overall library preparation time to <2 hours. The high conversion efficiency achievable with the KAPA HyperPrep Kit enables PCR-free workflows from as little as 100 ng input DNA. KAPA HyperPrep Kits without amplification reagents (07962339001, 07962355001 and 07962371001) are available for PCR-free workflows.

KAPA HyperPrep Kits contain a new, highly optimized Library Amplification Primer Mix, designed to eliminate or delay primer depletion during library amplification reactions performed with KAPA HiFi DNA polymerase. The primers in the mix are based on the P5 and P7 Illumina flow cell sequences, and are suitable for the amplification of libraries prepared with full-length adapters. User-supplied primer mixes may be used in combination with incomplete or custom adapters. Please contact  www.sequencing.roche.com/support for guidelines on the formulation of user-supplied library amplification primers.

The enzymes provided in this kit are temperature sensitive, and appropriate care should be taken during shipping and storage. KAPA HyperPrep Kits are shipped on dry ice or ice packs, depending on the country of destination. Upon receipt, immediately store enzymes and reaction buffers at -15°C to -25°C in a constant-temperature freezer. When stored under these conditions and handled correctly, the kit components will retain full activity until the expiry date indicated on the kit label.

The novel, one-tube KAPA HyperPrep chemistry leads to less adapter-dimer formation and carry-over. A single bead-based cleanup after adapter ligation is sufficient to remove unused adapter and adapter dimer, even at the high adapter:insert molar ratios recommended for low-input applications. If necessary, a second post-ligation (or size selection step) cleanup may be included to remove all traces of unused adapter and adapter-dimer, especially for PCR-free workflows 

For Research Use Only. Not for use in diagnostic procedures.