{ "ProductData": { "ID": "SYS_356", "ProductType": "System", "BrandName": "ePlex® system", "ProductNameAddition": "", "RegulatoryDisclaimer1": "For in vitro diagnostic use.", "DisclaimerGroup1": "IVD", "RegulatoryDisclaimer2": "", "DisclaimerGroup2": null, "RegulatoryDisclaimer3": "", "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "Genmark Customer Resource Center
Genmark Safety Data Sheets", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "GenMark ePlex system" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/ePlex_system_2.jpg", "ImageType": "Image main" }, "Product2Taxomony": { "Product2TaxomonyReferences": [ { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Molecular Lab", "NodeID": "010-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "999-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "999" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Molecular Lab", "NodeID": "010-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "999-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "999" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "09556621001", "MaterialDescription": "GM EPLEX BASE", "RegisteredProductName": "GM EPLEX BASE", "GTIN": "00857167005009", "ProductCategoryText": "Instruments", "OldMaterialNumber": "RM003001", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "en", "Value": "The True Sample-to-Answer Solution® ePlex Instrument automates all aspects of nucleic acid testing including extraction, amplification, and detection, combining electrowetting and GenMark’s eSensor® technology in a single-use cartridge. eSensor technology is based on the principles of competitive DNA hybridization and electrochemical detection, which is highly specific and is not based on fluorescent or optical detection.

Electrowetting, or digital microfluidics, uses electrical fields to directly manipulate discrete droplets on the surface of a hydrophobically coated printed circuit board (PCB). Sample and reagents are moved in a programmable fashion in the ePlex cartridge to complete all portions of the sample processing from nucleic acid extraction to detection.

A sample is loaded into the ePlex cartridge and the cartridge is placed into the ePlex Instrument. Nucleic acids are extracted and purified from the specimen via magnetic solid phase extraction. PCR is used to create double-stranded DNA, which is treated with exonuclease to create single-stranded DNA in preparation for eSensor detection.

The target DNA is mixed with ferrocene-labeled signal probes that are complementary to the specific targets on the panel. Target DNA hybridizes to its complementary signal probe and capture probes, which are bound to gold-plated electrodes, as shown below in Figure 1. The presence of each target is determined by voltammetry which generates specific electrical signals from the ferrocene-labeled signal probe.
 ", "Country": "XG", "Code": "Principle", "Name": "Principle" }, { "Language": "en", "Value": "The ePlex system is the only sample-to-answer solution on the market that streamlines the diagnostic workflow from physician order entry to the release of the final report.
  • Bi-directional LIS to automate and accelerate order entry and results reporting
  • Random and continuous access and a modular, scalable design to ensure capacity that meets peak season demand
  • Independently validated shortest hands-on time in the lab
  • Remote alerts to notify practitioners test results are available
  • Intuitive user interface with guided workflows to enable operation on every shift
  • Remote service capability to minimize system downtime and ensure patients and physicians have access to rapid test results
", "Country": "XG", "Code": "Product Description", "Name": "Product Description" }, { "Language": "tr", "Value": "ePlex sistemi, klinisyenlerin test istemini yapmalarından nihai raporun yayınlanmasına kadar olan tanı iş akışını kolaylaştıran gerçek bir numuneden yanıta çözümdür.
  • Test istemi girişini ve sonuçları otomatikleştirmek ve hızlandırmak için iki yönlü LIS raporlama
  • Yoğun sezon talebini karşılayan kapasiteyi sağlamak için rastgele ve sürekli erişim ve modüler, ölçeklenebilir tasarım
  • Laboratuvarda bağımsız olarak doğrulanmış en kısa uygulamalı çalışma süresi
  • Uygulayıcıların test sonuçlarını bilgilendirmek için uzaktan uyarılar
  • Her vardiyada çalışmayı etkinleştirmek için rehberli iş akışlarına sahip sezgisel kullanıcı arayüzü
  • Sistemin arıza süresini en aza indirmek ve hastaların ve doktorların test sonuçlarına hızlı erişimini sağlamak için uzaktan destek özelliği
", "Country": "XG", "Code": "Intended Use", "Name": "Intended Use" }, { "Language": "en", "Value": "System configurations

1-Tower System
  • 1 Base (#09556621001)
  • 1 Tower, 6-bay front tower fascia, 6 bays (#09782702001)
  • 1 short tower bolts (#09792074001, 3 pieces)
  • 1 Barcode scanner, Magnetic mount (#09792104001)

2-Tower System
  • 1 Base (#09556621001)
  • 2 Tower, 6-bay front tower fascia, 6 bays (#09782702001)
  • 2 short tower bolts (#09792074001, 3 pieces) *
  • 1 long tower bolts (#09792066001, 3 pieces) *
  • 1 Barcode scanner, Magnetic mount (#09792104001)

Note: Must order EITHER qty=2 short bolts OR qty=1 long bolts. The standard configuration is qty=2 short bolts. It is not necessary to order both.

3-Tower System
  • 1 Base (#09556621001)
  • 3 Tower, 6-bay front tower fascia, 6 bays (#09782702001)
  • 1 short tower bolts (#09792074001, 3 pieces)
  • 1 long tower bolts (#09792066001, 3 pieces)
  • 1 Barcode scanner, Magnetic mount (#09792104001)

4-Tower System
  • 1 Base (#09556621001)
  • 4 Tower, 6-bay front tower fascia, 6 bays (#09782702001)
  • 2 long tower bolts (#09792066001, 3 pieces)
  • 1 Barcode scanner, Magnetic mount (#09792104001)