cobas p 512 and cobas p 612 pre-analytical systems

cobas-p-612-pre-analytical-system-thumbnail

Adapting to today's needs. Flexible for tomorrow's demand.

This standalone sub automation solution is validated for cross contamination compliance and
therefore may be used to automate and simplify processes in clinical laboratories and blood banks.

Have any questions?
CONTACT US

Assay menu

View full List

Assay menu

Featured Product
New Product
Featured Product
New Product


cobas p 512 and cobas p 612 Technical Specifications

Throughput cobas p 512: Up to 1,400 primary tubes per hour (with sorting and archiving) 
cobas p 612: Up to 1,400 primary tubes per hour1 (with aliquoting, sorting and archiving)
Secondary Tube Sarstedt secondary tube 13x75 mm 
Sarstedt false bottom 13x75mm 
Greiner Bio-One false bottom 16mm twin tube
Dimensions cobas p 512: W approx. 6.2 ft x D (with touch screen) approx. 5.2 ft x H (incl. signal lamp) approx. 6.9 ft 
cobas p 612: W approx. 10.4 ft x D (with touch screen) approx. 6.1 ft x H (incl. signal lamp) approx. 6.5 ft
Weight cobas p 512: approx. 1,918 lbs including centrifuge 
cobas p 612: approx. 2,425 lbs
Power cobas p 512: 115 V, 60 Hz, 4950 VA 
cobas p 612: 115 V, 60 Hz, 1800 VA
Centrifuge One centrifuge – Hettice Rotanta 46 RSC Robotic
Throughput of p 471 centrifuge
Up to 495 tubes/hr. with 5 min. spin
Sample Tube cobas p 512: Accepts most 3, 5, 7 or 10 ml plastic tubes with an external tube diameter between 11.5 and 15.5 mm and a total height between 65.5 and 108 mm 
cobas p 612: Accepts most 3, 5, 7 or 10 ml plastic tubes 
Both systems are able to open sample tubes with hemogard, rubber stopper or screw cap type closure
Sample Carrier RD Hitachi MPA racks (5 positions) for input and output buffer 
Other third-party racks possible
Aliquot Tips cobas p 612: Use of disposable pipette tips for secondary tube generation: 1100 μl volume conductive or 1000 μl volume non-conductive (depending on the selected camera) 
384 tips on board in 4 tip racks
Operating Conditions For indoor use up to 2000 m above sea level
Operating Temperature +15°C to +30°C (+59°F to +86°F)
Air Conditions 20–80% relative humidity
Compressed Air D\Dry and oil free, min 6.0 bar (87.02 psi), max 8.0 bar (116.03 psi) 
Consumption approx. 40.0 l (10.6 gals) per min 
Consumption approx. 66.0 l (17.4 gals) per min with recap unit
Sample Identification Positive sample identification via bar code; able to handle most of the standard bar code formats such as Interleaved 2 of 5, Code 39, Codabar (NW 7), Code 128, others2
Interface ASTM protocol 
Network connection via TCP/IP or serial connection via RS 232