Cell Marque - Instructions for UseCell Marque - Safety Data Sheet For in vitro diagnostic use. Membrane Others C4d SP91 IVD Kidney (Reject Transplant) Tonsil/Lymph Node anti-C4d (SP91) Rabbit Monoclonal Primary Antibody RTD000707 Rabbit SP91 06732364001 C4d (SP91) PAb, Cell Marque C4d (SP91) 00841683101444 Reagents, kits 50 tests Not Available true Le C4d (SP91) Rabbit Monoclonal Primary Antibody est destiné à un usage en laboratoire pour détecter la protéine C4d dans les tissus humains fixés au formol et enrobés à la paraffine, colorés par immunohistochimie (IHC) qualitative sur les instruments BenchMark IHC/ISH. Ce produit doit être interprété par un pathologiste compétent en parallèle avec un examen histologique, les informations cliniques pertinentes et les contrôles appropriés. Cet anticorps est destiné à être utilisé aux fins de diagnostic in vitro (IVD). fr anti-C4d (SP91) Rabbit Monoclonal Primary Antibody (this antibody) may be used as the primary antibody for immunohistochemical staining of formalin-fixed, paraffin-embedded tissue sections. In general, immunohistochemical staining allows the visualization of antigens via the sequential application of a specific antibody (primary antibody) to the antigen, a secondary antibody (link antibody) to the primary antibody, an enzyme complex and a chromogenic substrate with interposed washing steps. The enzymatic activation of the chromogen results in a visible reaction product at the antigen site. The specimen may then be counterstained and a coverslip applied. Results are interpreted using a light microscope and aid in the differential diagnosis of pathophysiological processes, which may or may not be associated with a particular antigen.This antibody is optimally diluted to be compatible with VENTANA detection kits and BenchMark IHC/ISH instruments. Refer to the Tables in the Instructions for Use section for recommended staining protocols. Each step in the staining protocol includes incubation for a precise time at a specifi c temperature. At the end of each incubation step, the sections are rinsed by the BenchMark IHC/ISH instruments to stop the reaction and remove unbound material that would hinder the desired reaction in subsequent steps. To minimize evaporation of the aqueous reagents from the specimen-containing slide, a coverslip solution is applied in the slide stainer. For more detailed information on instrument operation, refer to the appropriate BenchMark IHC/ISH instruments Operator’s Manual. en
Vous êtes actuellement sur le site Web mondial. Modifiez la localisation pour afficher les options de langues ou accédez à eLabDoc, le référentiel des documents des produits.