Cell Marque - Instructions for UseCell Marque - Safety Data Sheet For in vitro diagnostic use. Nucleus Others SV40 MRQ-4 IVD SV80 or SV T2 cells SV40 infected tissue SV40 (MRQ-4) Mouse Monoclonal Antibody RTD001145 Mouse MRQ-4 05 973 775 001 5 973 775 001 05973775001 5973775001 05973775001 SV-40 (MRQ-4) PAb, Cell Marque SV40 (MRQ-4) 00841683101055 Reagents, kits 50 tests Not Available undefined Le SV40 (MRQ-4) Mouse Monoclonal Antibody est destiné à un usage en laboratoire pour détecter le grand antigène T du virus simien 40 (SV40) dans les tissus humains fixés au formol et enrobés à la paraffine, colorés par un test qualitatif d’immunohistochimie (IHC) sur les instruments BenchMark IHC/ISH.
Ce produit doit être interprété au microscope photonique par un pathologiste qualifié en association avec l’examen histologique, les informations cliniques pertinentes et les témoins appropriés.
Cet anticorps est destiné au diagnostic in vitro (DIV). fr SV40 (MRQ-4) Mouse Monoclonal Antibody (this antibody) may be used as the primary antibody for immunohistochemical staining of formalin-fixed, paraffin-embedded tissue sections. In general, immunohistochemical staining allows the visualization of antigens via the sequential application of a specific antibody (primary antibody) to the antigen, a secondary antibody (link antibody) to the primary antibody, an enzyme complex and a chromogenic substrate with interposed washing steps. The enzymatic activation of the chromogen results in a visible reaction product at the antigen site. The specimen may then be counterstained and a coverslip applied. Results are interpreted using a light microscope and aid in the differential diagnosis of pathophysiological processes, which may or may not be associated with a particular antigen. This antibody is optimally diluted to be compatible with VENTANA detection kits and BenchMark IHC/ISH instruments. Refer to the Tables in the Recommended Protocol section for recommended staining protocols. Each step in the staining protocol includes incubation for a precise time at a specific temperature. At the end of each incubation step, the sections are rinsed by the BenchMark IHC/ISH instruments to stop the reaction and remove unbound material that would hinder the desired reaction in subsequent steps. To minimize evaporation of the aqueous reagents from the specimen-containing slide, a coverslip solution is applied in the slide stainer. For more detailed information on instrument operation, refer to the appropriate BenchMark IHC/ISH instruments User Guide. en
Vous êtes actuellement sur le site Web mondial. Modifiez la localisation pour afficher les options de langues ou accédez à eLabDoc, le référentiel des documents des produits.