{ "ProductData": { "RelatedLinks": "", "RegulatoryDisclaimer1": "For in vitro diagnostic use.", "RegulatoryDisclaimer2": "", "StainLocalization": [ "" ], "ProductType": "Instrument", "DisclaimerGroup2": null, "ProductNameGlobal": "cobas b 101", "DisclaimerGroup1": "IVD", "ControlTissue": [ "" ], "BrandName": "cobas b 101 system", "LicenseDisclaimers": [ ], "Isotypes": "", "RegulatoryDisclaimer3": "", "ID": "INS_2892", "ProductNameAddition": "", "Species": [ "" ], "Clone": "" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/cobas b 101.jpg", "ImageType": "Image main" }, "Product2Taxomony": { "Product2TaxomonyReferences": [ { "StructureSystemIdentifier": "1", "StructureSystemName": "GPCH", "NodeName": "cobas b 101", "NodeID": "7075" }, { "StructureSystemIdentifier": "OWP_Organization", "StructureSystemName": "Organization", "NodeName": "Clinical Chemistry and Immunoassay", "NodeID": "10-10-20-20-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeName": "cobas", "NodeID": "110" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeName": "Point of Care Testing", "NodeID": "110-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeName": "Blood Gas and Electrolytes", "NodeID": "021" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeName": "NOT APPLICABLE", "NodeID": "999-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeName": "Critical Care", "NodeID": "11-00-00" } ] }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "1", "StructureSystemName": "GPCH", "NodeName": "cobas b 101", "NodeID": "7075" }, { "StructureSystemIdentifier": "OWP_Organization", "StructureSystemName": "Organization", "NodeName": "Clinical Chemistry and Immunoassay", "NodeID": "10-10-20-20-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeName": "cobas", "NodeID": "110" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeName": "Point of Care Testing", "NodeID": "110-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeName": "Blood Gas and Electrolytes", "NodeID": "021" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeName": "NOT APPLICABLE", "NodeID": "999-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeName": "NOT APPLICABLE", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeName": "Critical Care", "NodeID": "11-00-00" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "06378668190", "MaterialDescription": "cobas b 101 instrument", "RegisteredProductName": "cobas b 101 system", "GTIN": "04015630930692", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "", "PackSizeDescPIM360": "", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "06378668016", "MaterialDescription": "cobas b 101 (DE FR NL IT)", "RegisteredProductName": "cobas b 101 system", "GTIN": "07613336204269", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "", "PackSizeDescPIM360": "", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "fr", "Value": "Le cobas b 101 est un appareil de diagnostic in vitro pour l’évaluation quantitative de tests de chimie clinique et d’immunodosages à l’aide des disques de test cobas b 101. L’appareil cobas b 101 est destiné aux tests au chevet du patient. Il n’est pas prévu pour les autotests.", "Country": "XG", "Code": "Intended Use", "Name": "Intended Use" } ] } } ] }

cobas b 101 system

Le bilan lipidique, les HbA1c et les CRP en délocalisé

Image produit du sytème cobas b 101
Avez-vous des questions ?
Contact

Performances conformes aux recommandations

  • Le système cobas b 101 est conforme à toutes les normes et valeurs pertinentes (IFCC, DCCT/NGSP et NCEP)1,2,3

 

Un fonctionnement simple et sûr

 

  • Le test est réalisé sur un échantillon de sang capillaire prélevé au bout du doigt
  • Pas de maintenance ni de calibration à réaliser, guide de l'opérateur graphique pour une utilisation simplifiée

 

Des délais d'exécution rapides

 

  • Les résultats du test sont disponibles en 6 minutes seulement (CRP en moins de 4 minutes, double analyse en 15 minutes)4.
  • Un large choix de tests d’HbA1c, de profil lipidique et CRP et de doubles tests HbA1c/profil lipidique

 

Spécifications4

 

  • Facile à utiliser grâce à son grand écran tactile, son clavier complet et la prise en charge de plusieurs langues 
  • Solide, sans entretien et sans calibration, plage de température et d’humidité de fonctionnement étendue
  • Connectable aux systèmes informatiques existants par l'application cobas POC Infinity
  • Transmission des valeurs mesurées via une imprimante ou vers le système d'information du laboratoire
  • Possibilité de télécharger les données sur une clé USB ou directement sur le PC

 

Caractéristiques du disque4

 

  • Prélèvement simple des échantillons (pas besoin de tubes capillaires ni de pipettes
  • Petit volume d'échantillon : 2 µl pour l'HbA1c,19 µl pour le profil lipidique et 12 μL pour la CRP
  • Les disques sont codés par couleur et clairement étiquetés.
  • Sécurité du travail élevée grâce au couvercle à charnière
  • Les disques peuvent être conservés pendant plus de 13 mois à température ambiante (+2°C à +30°C)1,2,3
Système cobas b 101

Références

 

  1. Fiche technique test cobas HbA1c, v2, 09-2019.
  2. Fiche technique gamme cobas Lipid Panel, v4.0., 03-2020
  3. Fiche Technique test cobas CRP, v2, 03-2020. 
  4. Manuel utilisateur cobas b 101, v2.0, 03-2018

Le cobas b 101 est un appareil de diagnostic in vitro pour l’évaluation quantitative de tests de chimie clinique et d’immunodosages à l’aide des disques de test cobas b 101. L’appareil cobas b 101 est destiné aux tests au chevet du patient. Il n’est pas prévu pour les autotests.
Dispositif médical de diagnostic in vitro. Classe A
Fabricant : Roche Diagnostics GmbH (Allemagne) – Distributeur : Roche Diagnostics France
Lire attentivement les instructions figurant dans le manuel d’utilisation.

Mis à jour : 09/2022

Aperçu

Commander

Documents techniques

Caractéristiques techniques1

  • Taille de l’échantillon

    HbA1c : 2 μL
    Profil lipidique : 19 μL
    CRP: 12 μL

  • Matériel pour les échantillons

    HbA1c :
    Sang total capillaire, sang total veineux avec anticoagulant (EDTA ou héparine)

     

     

     

    Profil lipidique : 
    Sang total capillaire, sang total veineux avec anticoagulant (EDTA)

     

     

     

    CRP : Sang total capillaire, sang total veineux, sérum ou plasma avec anticoagulant (EDTA ou héparine)

     

     

     

     

     

     

     

  • Domaines de mesure

    Tests HbA1c :
    20 - 130 mmol/mol (IFCC) ou 4–14 % (DCCT/NGSP)

    Tests Lipid :
    CHOL: 50–500 mg/dL ou 1.28–12.95 mmol/L
    TRIGL : 45–650 mg/dL ou 0.50–7.35 mmol/L
    HDL-CHOL : 15–100 mg/dL ou 0.38–2.60 mmol/L

    CRP : 
    3.0–400 mg/L ou 0.30–40.0 mg/dL

  • Température d'entreposage

    2 à 30 °C

  • Stabilité du test

    Non ouvert : 13 à 16 mois
    Ouvert : 20 minutes