{ "ProductData": { "ID": "SYS_249", "ProductType": "System", "BrandName": "cobas® 8100 automated workflow series", "ProductNameAddition": "", "RegulatoryDisclaimer1": "For in vitro diagnostic use.", "DisclaimerGroup1": "IVD", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "cobas 8100 automated workflow series" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/qcobas-8100.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeID": "10-000-00", "StructureNodeStatus": "valid", "NodeName": "Analyzer Instruments and Systems" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeID": "110", "StructureNodeStatus": "valid", "NodeName": "cobas" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeID": "050-00", "StructureNodeStatus": "valid", "NodeName": "Core Lab" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeID": "130", "StructureNodeStatus": "valid", "NodeName": "Lab automation" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeID": "999-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "07123876001", "MaterialDescription": "cobas 8100 RSF (Restopper Flex-caps)", "RegisteredProductName": "cobas 8100 RSF (Restopper Flex-caps)", "GTIN": "04015630943753", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08010595001", "MaterialDescription": "cobas 8100 2nd BCL (BCL and modi kit)", "RegisteredProductName": "cobas 8100 BCL and modi kit", "GTIN": "07613336142561", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08307881001", "MaterialDescription": "CSCM for cobas 8100", "RegisteredProductName": "CSCM for cobas 8100", "GTIN": "07613336153550", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07439954001", "MaterialDescription": "c8100 v2 BRF incl. Conn.", "RegisteredProductName": "c8100 v2 BRF incl. Conn.", "GTIN": "04015630943838", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08015589001", "MaterialDescription": "cobas 8100 RSS (Restopper Screw Cap)", "RegisteredProductName": "cobas 8100 Restopper Screw Cap", "GTIN": "07613336142547", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123868001", "MaterialDescription": "cobas 8100 ACU", "RegisteredProductName": "cobas 8100 ACU", "GTIN": "04015630943746", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08015597001", "MaterialDescription": "cobas 8100 2nd IPB (Input Buffer)", "RegisteredProductName": "cobas 8100 2nd Input Buffer", "GTIN": "07613336142554", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07439822001", "MaterialDescription": "c8100 v2 Type Alpha (IPB,DSP,OBS,CRW,CU)", "RegisteredProductName": "c8100 v2 Alpha (IPB,DSP,OBS,CRW,CU)", "GTIN": "04015630943364", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07439920001", "MaterialDescription": "c8100v2 Beta(IPB,DSP,BCL,AQM,OBS,CRW,CU)", "RegisteredProductName": "c8100 v2 Beta (IPB,DSP,BCL,AQM,OBS,CRW,CU)", "GTIN": "04015630943371", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123892001", "MaterialDescription": "cobas 8100 OBS (Output Buffer/Sorter)", "RegisteredProductName": "cobas 8100 OBS (Output Buffer/Sorter)", "GTIN": "04015630943760", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07440073001", "MaterialDescription": "c8100 v2 SCM", "RegisteredProductName": "c8100 v2 SCM", "GTIN": "04015630943906", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123922001", "MaterialDescription": "c 8100 BCL (Barcode Labeler/Tube Feeder)", "RegisteredProductName": "cobas 8100 BCL (Barcode Labeler/Tube Feeder)", "GTIN": "04015630943791", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123914001", "MaterialDescription": "cobas 8100 AOB", "RegisteredProductName": "cobas 8100 AOB", "GTIN": "04015630943777", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07787138001", "MaterialDescription": "cobas 8100 AQM (Aliquoter Module)", "RegisteredProductName": "cobas 8100 Aliquoter Module", "GTIN": "07613336101254", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07787146001", "MaterialDescription": "cobas 8100 DSP (Destopper)", "RegisteredProductName": "cobas 8100 Destopper", "GTIN": "07613336101537", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Name": "Intended Use", "Value": "Intended use for US only

The cobas® 8100 automated workflow series is an automated, software-controlled system for processing patient samples before they go for analysis.

The system is designed to centrifuge patient samples, remove and insert sample tube caps as required, apply barcode labels to secondary tubes, and prepare aliquots from primary samples. It can sort samples for online and offline analysis, and temporarily store samples. The system transports individual samples between modules, and to connected analyzers.

The cobas® 8100 automated workflow series is intended for use with analyzers that perform tests in the areas of immunology, clinical chemistry, coagulation, urinalysis, and hematology.

Supporting information for US only

The cobas® 8100 automated workflow series is an in vitro diagnostic (IVD) medical equipment.

Intended purpose for EU/EFTA and outside US

The cobas® 8100 automated workflow series is an automated, software-controlled system for processing patient samples before they go for analysis.

The system is designed to centrifuge patient samples, remove and insert sample tube caps as required, apply barcode labels to secondary tubes, and prepare aliquots from primary samples. It can sort samples for online and offline analysis, and temporarily store samples. The system transports individual samples between modules, and to connected analyzers.

The cobas® 8100 automated workflow series is intended for use with analyzers that perform tests in the areas of immunology, clinical chemistry, coagulation, urinalysis, and hematology.

Supporting information for EU/EFTA and outside US

The cobas® 8100 automated workflow series is a fully automated system intended for sample workflow management.

The cobas® 8100 automated workflow series is a fully automated and software controlled pre-analytical system for processing samples before and after online or offline analysis without assay testing function.", "Language": "en", "Country": "XG", "Code": "Intended Use" } ] } } ] }

cobas® 8100 automated workflow series

IVD For in vitro diagnostic use.
<b>cobas</b><sup>®</sup> 8100 automated workflow series

Quality and reliability you can trust

The cobas 8100 intelligent tube transport provides a short, predictable time to results, including the ability to prioritise emergency samples. With flexible workflows, early error detection and fully automated add-on handling, the cobas 8100 allows for personalised solutions to suit individual laboratory needs, guaranteeing that quality comes first.

cobas 8100 automated workflow series
Do you have any questions?
Contact us

Whether your laboratory’s challenge is throughput, turnaround times, or both, the cobas 8100 automated workflow series can fulfil your needs, enabling you to work faster and more efficiently.

Quality comes first

 

At an early pre-analytical stage, Roche automation solutions perform an extensive inspection of samples for maximum workflow efficiency:

  • Sample quality check via a high-resolution optical camera which enables detection of standard, haemolytic, lipaemic and icteric samples.
  • Tube type identification.
  • Laser liquid level detection.

 

Workflow your way

 

Personalised workflows enable you to choose from primary, aliquot or mixed workflow:

  • Primary sample workflow – if the focus is on cost efficiency.
  • Aliquot workflow – if the focus is on sample integrity and parallel testing.
  • Mixed workflow – to optimise the benefits of both workflows.

 

Short and predictable time to results

 

  • 3D intelligent tube transport helps laboratories to improve patient care by offering reliable results within predictably short turnaround times, even during peak workflows.
  • Multi-level and bidirectional tube transport: empty tube holders and holders with tubes run separately to avoid traffic jams. 
  • Tubes always have a defined destination and do not circle the track, guaranteeing first-in-first-out sample processing.
  • Tubes can bypass modules if processing is not required.
  • Prioritised STAT workflow.

 

Flexible tube storage

 

A solution with cobas 8100 offers three storage concepts, ensuring fast access as soon as a tube is needed. 

  • Short-term storage for an immediate re-run
  • Mid-term storage in the Add-on Buffer Module – for optimised add-on request processing within the same day
  • Long-term storage

 

Maximum consolidation

 

  • The broad reagent portfolio consolidates 98% or more of routine serum work area assays.
  • Immuno & clinical chemistry, haematology, coagulation, selective third-party analysers and archiving can all be integrated.
  • Fully automate the laboratory process from sample entry to archive.
  • Combine post-analytic solutions with the add-on buffer module for additional requests within one day.

Overview

Ordering Information

Back     Next