Det verkar som att du använder inkognito mode/privat surfningsläge eller en annonsblockerare, vilket kan försämra din upplevelse på webbplatsen. För en bättre upplevelse, inaktivera annonsblockerare och visa webbplatsen i icke-privat surfningsläge.
For in vitro diagnostic use. Others cobas TV MG Test 5800-6800-8800 IVD cobas® TV/MG PID00000167 Qualitative nucleic acid test for use on the cobas® 5800/6800/8800 Systems 09040633190 KIT COBAS 58/68/8800 TV/MG 384T IVD cobas TV/MG 00875197006902 Reagents, kits 1 kit 384 tests true cobas ® TV/MG for use on the cobas ® 5800/6800/8800 Systems is an automated, qualitative in vitro diagnostic test, that utilizes real-time polymerase chain reaction (PCR), for the direct detection of Trichomonas vaginalis (TV) and/or Mycoplasma genitalium (MG) DNA in male and female urine, clinician-instructed self-collected vaginal swab specimens, clinician-collected vaginal swab specimens, endocervical swab specimens, clinician-instructed self-collected meatal swab specimens, clinician-collected meatal swab specimens, all collected in cobas ® PCR Media (Roche Molecular Systems, Inc.), and cervical specimens collected in PreservCyt ® Solution. This test is intended as an aid in the diagnosis of TV and MG caused disease in both symptomatic and asymptomatic individuals. en cobas® TV/MG is based on fully automated sample preparation (nucleic acid extraction and purification) followed by PCR amplification and detection. The cobas® 5800 System is designed as one integrated instrument. The cobas ® 6800/8800 Systems consist of the sample supply module, the transfer module, the processing module, and the analytic module. Automated data management is performed by the cobas® 5800 System or cobas® 6800/8800 software which assigns test results for all tests as positive, negative or invalid. Results can be reviewed directly on the system screen, exported, or printed as a report.Nucleic acid from patient samples, external controls and added internal control DNA (DNA-IC) molecules is simultaneously extracted. In summary, bacterial nucleic acid is released by addition of proteinase and lysis reagent to the sample. The released nucleic acid binds to the silica surface of the added magnetic glass particles. Unbound substances and impurities, such as denatured protein, cellular debris and potential PCR inhibitors are removed with subsequent wash steps and purified nucleic acid is eluted from the magnetic glass particles with elution buffer at elevated temperature.Selective amplification of target nucleic acid from the sample is achieved by the use of target-specific forward and reverse primers for TV and MG which are selected from highly-conserved regions within the respective target organism. TV is detected by one selective set of primers and a probe, while MG uses two sets targeting separated regions (dual-target). Selective amplification of DNA IC is achieved by the use of sequence-specific forward and reverse primers which are selected to have no homology with either the TV or MG target regions. A thermostable DNA polymerase enzyme is used for PCR amplification. The target and DNA-IC sequences are amplified simultaneously utilizing a universal PCR amplification profile with predefined temperature steps and number of cycles. The master mix includes deoxyuridine triphosphate (dUTP), instead of deoxythimidine triphosphate (dTTP), which is incorporated into the newly synthesized DNA (amplicon). Any contaminating amplicon from previous PCR runs are eliminated by the AmpErase enzyme, which is included in the PCR master mix, during the first thermal cycling step.15 However, newly formed amplicon are not eliminated since the AmpErase enzyme is inactivated once exposed to temperatures above 55°C.The cobas® TV/MG master mix contains one detection probe specific for the TV target sequence, two detection probes specific for the MG target sequences and one for the DNA-IC. The probes are labeled with target specific fluorescent reporter dyes allowing simultaneous detection of TV target, MG targets and DNA-IC in three different target channels.16,17 When not bound to the target sequence, the fluorescent signal of the intact probes is suppressed by a quencher dye. During the PCR amplification step, hybridization of the probes to the specific single-stranded DNA template results in cleavage of the probe by the 5' to 3' exonuclease activity of the DNA polymerase resulting in separation of the reporter and quencher dyes and the generation of a fluorescent signal. With each PCR cycle, increasing amounts of cleaved probes are generated and the cumulative signal of the reporter dye increases concomitantly. Real-time detection and discrimination of PCR products is accomplished by measuring the fluorescence of the released reporter dyes for the TV and MG targets and DNA-IC, respectively.15. Longo MC, Berninger, MS, Hartley JL. Use of uracil DNA glycosylase to control carry-over contamination in polymerase chain reactions. Gene. 1990; 93:125-8.16. Higuchi R, Dollinger, G, Walsh PS, Griffith R. Simultaneous amplification and detection of specific DNA sequences. Bio/Technology 1992; 10:413-7.17. Heid CA, Stevens J, Livak JK, Williams PM. Real time quantitative PCR. Genome Research. 1996; 6:986-94. en
cobas® TV/MG
Qualitative nucleic acid test for use on the cobas® 5800/6800/8800 Systems