{ "ProductData": { "ID": "INS_6050", "ProductType": "Instrument", "BrandName": "cobas® liat system", "ProductNameAddition": "", "RegulatoryDisclaimer1": "For in vitro diagnostic use.", "DisclaimerGroup1": "IVD", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "cobas liat" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/INS_6050_cobas_Liat.jpg", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "1", "StructureSystemName": "GPCH", "StructureNodeStatus": "", "NodeName": "", "NodeID": "9274" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "cobas", "NodeID": "110" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Point of Care Testing", "NodeID": "110-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "PCR/qPCR", "NodeID": "210-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "RT-PCR/qRT-PCR", "NodeID": "300-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "valid", "NodeName": "Critical Care", "NodeID": "11-00-00" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "07341920190", "MaterialDescription": "cobas LIAT SYSTEM", "RegisteredProductName": "cobas® Liat® Analyzer", "GTIN": "07613336100097", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ { "ProductID": "RMD-Liat-CDIFF-001", "BrandName": "cobas® Cdiff", "ProductNameAddition": "Nucleic acid test for use on the cobas® liat system", "ReferenceType": "Reagent", "Classification": [ { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "03-0117", "StructureGroupPath": "Molecular->cobas Cdiff - LIAT", "StructureGroupName": "cobas Cdiff - LIAT", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "20-000-00", "StructureGroupPath": "Assays Reagents and Strips", "StructureGroupName": "Assays Reagents and Strips", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "210-00", "StructureGroupPath": "PCR/qPCR", "StructureGroupName": "PCR/qPCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "09-00-00", "StructureGroupPath": "Colostrium difficile", "StructureGroupName": "Colostrium difficile", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "010-00", "StructureGroupPath": "Molecular Lab", "StructureGroupName": "Molecular Lab", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "13-00-00", "StructureGroupPath": "Gastroenterology", "StructureGroupName": "Gastroenterology", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "17-00-00", "StructureGroupPath": "Infectious Diseases", "StructureGroupName": "Infectious Diseases", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "14-00-00", "StructureGroupPath": "Diarrhoeal disease", "StructureGroupName": "Diarrhoeal disease", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "18-00-00", "StructureGroupPath": "Gastrointestinal infections", "StructureGroupName": "Gastrointestinal infections", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "21-00-00", "StructureGroupPath": "Inflammation", "StructureGroupName": "Inflammation", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "090", "StructureGroupPath": "Microbiology", "StructureGroupName": "Microbiology", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "19-00-00", "StructureGroupPath": "Healthcare-associated infections", "StructureGroupName": "Healthcare-associated infections", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "19-00-00", "StructureGroupPath": "Qualitative Detection", "StructureGroupName": "Qualitative Detection", "StructureNodeStatus": "valid" } ] }, { "ProductID": "RMD-Liat-INFL-002", "BrandName": "cobas® Influenza A/B & RSV", "ProductNameAddition": "Nucleic acid test for use on the cobas® liat system", "ReferenceType": "Reagent", "Classification": [ { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "03-0119", "StructureGroupPath": "Molecular->cobas Influenza A/B and RSV - LIAT", "StructureGroupName": "cobas Influenza A/B and RSV - LIAT", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "20-000-00", "StructureGroupPath": "Assays Reagents and Strips", "StructureGroupName": "Assays Reagents and Strips", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "210-00", "StructureGroupPath": "PCR/qPCR", "StructureGroupName": "PCR/qPCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "26-00-00", "StructureGroupPath": "Influenza virus", "StructureGroupName": "Influenza virus", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "44-00-00", "StructureGroupPath": "Respiratory syncytial virus (RSV)", "StructureGroupName": "Respiratory syncytial virus (RSV)", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "010-00", "StructureGroupPath": "Molecular Lab", "StructureGroupName": "Molecular Lab", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "17-00-00", "StructureGroupPath": "Infectious Diseases", "StructureGroupName": "Infectious Diseases", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "20-00-00", "StructureGroupPath": "Pulmonology", "StructureGroupName": "Pulmonology", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "35-00-00", "StructureGroupPath": "Respiratory tract infections", "StructureGroupName": "Respiratory tract infections", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "19-00-00", "StructureGroupPath": "Qualitative Detection", "StructureGroupName": "Qualitative Detection", "StructureNodeStatus": "valid" } ] }, { "ProductID": "RMD-Liat-STREPA-001", "BrandName": "cobas® Strep A", "ProductNameAddition": "Nucleic acid test for use on the cobas® liat system", "ReferenceType": "Reagent", "Classification": [ { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "03-0121", "StructureGroupPath": "Molecular->cobas Strep A - LIAT", "StructureGroupName": "cobas Strep A - LIAT", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "20-000-00", "StructureGroupPath": "Assays Reagents and Strips", "StructureGroupName": "Assays Reagents and Strips", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "210-00", "StructureGroupPath": "PCR/qPCR", "StructureGroupName": "PCR/qPCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "48-00-00", "StructureGroupPath": "Streptococcus (Strep)", "StructureGroupName": "Streptococcus (Strep)", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "010-00", "StructureGroupPath": "Molecular Lab", "StructureGroupName": "Molecular Lab", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "17-00-00", "StructureGroupPath": "Infectious Diseases", "StructureGroupName": "Infectious Diseases", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "20-00-00", "StructureGroupPath": "Pulmonology", "StructureGroupName": "Pulmonology", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "35-00-00", "StructureGroupPath": "Respiratory tract infections", "StructureGroupName": "Respiratory tract infections", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "19-00-00", "StructureGroupPath": "Qualitative Detection", "StructureGroupName": "Qualitative Detection", "StructureNodeStatus": "valid" } ] }, { "ProductID": "RMD-Liat-SARS-001", "BrandName": "cobas® SARS-CoV-2 & Influenza A/B", "ProductNameAddition": "Nucleic acid test for use on the cobas® liat system", "ReferenceType": "Reagent", "Classification": [ { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "03-0705", "StructureGroupPath": "Molecular->cobas SARS-CoV-2 and Influenza A/B - LIAT", "StructureGroupName": "cobas SARS-CoV-2 and Influenza A/B - LIAT", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "20-000-00", "StructureGroupPath": "Assays Reagents and Strips", "StructureGroupName": "Assays Reagents and Strips", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-02-05-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Molecular Lab->Infectious Disease", "StructureGroupName": "Infectious Disease", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "10-00-00", "StructureGroupPath": "Coronavirus (COVID)", "StructureGroupName": "Coronavirus (COVID)", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "26-00-00", "StructureGroupPath": "Influenza virus", "StructureGroupName": "Influenza virus", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "110-00", "StructureGroupPath": "Point of Care Testing", "StructureGroupName": "Point of Care Testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "17-00-00", "StructureGroupPath": "Infectious Diseases", "StructureGroupName": "Infectious Diseases", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "20-00-00", "StructureGroupPath": "Pulmonology", "StructureGroupName": "Pulmonology", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "35-00-00", "StructureGroupPath": "Respiratory tract infections", "StructureGroupName": "Respiratory tract infections", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "300-00", "StructureGroupPath": "RT-PCR/qRT-PCR", "StructureGroupName": "RT-PCR/qRT-PCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "11-00-00", "StructureGroupPath": "Critical Care", "StructureGroupName": "Critical Care", "StructureNodeStatus": "valid" } ] }, { "ProductID": "INS_6680", "BrandName": "cobas® infinity edge unite", "ProductNameAddition": "cobas infinity edge unite is a software as a service (SaaS) offering that seamlessly connects POC devices used in ambulatory care settings.", "ReferenceType": "Software", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "10048", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "60-000-00", "StructureGroupPath": "Electronic Services", "StructureGroupName": "Electronic Services", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "110-00", "StructureGroupPath": "Point of Care Testing", "StructureGroupName": "Point of Care Testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "051", "StructureGroupPath": "Digital solutions", "StructureGroupName": "Digital solutions", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "11-00-00", "StructureGroupPath": "Critical Care", "StructureGroupName": "Critical Care", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] }, { "ProductID": "RMD-Liat-SARS-003", "BrandName": "cobas® SARS-CoV-2", "ProductNameAddition": "Nucleic acid test for use on the cobas® liat system", "ReferenceType": "Reagent", "Classification": [ { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "03-0720", "StructureGroupPath": "Molecular->cobas SARS-CoV-2 - LIAT", "StructureGroupName": "cobas SARS-CoV-2 - LIAT", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "210-00", "StructureGroupPath": "PCR/qPCR", "StructureGroupName": "PCR/qPCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "20-000-00", "StructureGroupPath": "Assays Reagents and Strips", "StructureGroupName": "Assays Reagents and Strips", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Organization", "NameofStructureSystem": "Organization", "StructureNodeID": "01-01-02-05-00", "StructureGroupPath": "Roche Diagnostics Solution (RDS)->Customer Areas->Molecular Lab->Infectious Disease", "StructureGroupName": "Infectious Disease", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "10-00-00", "StructureGroupPath": "Coronavirus (COVID)", "StructureGroupName": "Coronavirus (COVID)", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "110-00", "StructureGroupPath": "Point of Care Testing", "StructureGroupName": "Point of Care Testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "17-00-00", "StructureGroupPath": "Infectious Diseases", "StructureGroupName": "Infectious Diseases", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "20-00-00", "StructureGroupPath": "Pulmonology", "StructureGroupName": "Pulmonology", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "35-00-00", "StructureGroupPath": "Respiratory tract infections", "StructureGroupName": "Respiratory tract infections", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "19-00-00", "StructureGroupPath": "Qualitative Detection", "StructureGroupName": "Qualitative Detection", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "11-00-00", "StructureGroupPath": "Critical Care", "StructureGroupName": "Critical Care", "StructureNodeStatus": "valid" } ] }, { "ProductID": "INS_7034", "BrandName": "cobas® infinity edge smart", "ProductNameAddition": "cobas infinity edge smart brings in an easy to use serviceability interface which gives you control over updates, saves you time and allows you to manage any problems with ease.", "ReferenceType": "Software", "Classification": [ { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "110-00", "StructureGroupPath": "Point of Care Testing", "StructureGroupName": "Point of Care Testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "60-000-00", "StructureGroupPath": "Electronic Services", "StructureGroupName": "Electronic Services", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "051", "StructureGroupPath": "Digital solutions", "StructureGroupName": "Digital solutions", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "10512", "StructureGroupPath": "Licensed IT Products->Lab Insights->Lab Applications->POC Software Solution->edge smart", "StructureGroupName": "edge smart", "StructureNodeStatus": "valid" } ] }, { "ProductID": "INS_6818", "BrandName": "cobas® infinity POC", "ProductNameAddition": "cobas® infinity POC is an integrated web based application with open connectivity that helps manage Point of Care Testing from a single location.", "ReferenceType": "Software", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "10184", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "60-000-00", "StructureGroupPath": "Electronic Services", "StructureGroupName": "Electronic Services", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "110", "StructureGroupPath": "cobas", "StructureGroupName": "cobas", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "110-00", "StructureGroupPath": "Point of Care Testing", "StructureGroupName": "Point of Care Testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "051", "StructureGroupPath": "Digital solutions", "StructureGroupName": "Digital solutions", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "130", "StructureGroupPath": "Lab automation", "StructureGroupName": "Lab automation", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "11-00-00", "StructureGroupPath": "Critical Care", "StructureGroupName": "Critical Care", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" } ] } ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "es", "Value": "El cobas® liat Analyzer es un instrumento automatizado para análisis de ácidos nucleicos que, cuando se utiliza junto con los tubos de ensayo cobas® liat para realizar pruebas de diagnóstico in vitro, se denomina de forma genérica cobas® liat System. En un tubo de ensayo cobas® liat ​​​​​​, el instrumento lleva a cabo la preparación de reactivos, el enriquecimiento de fragmentos objetivo, la eliminación de inhibidores, la extracción de ácidos nucleicos, la amplificación de los mismos mediante la reacción en cadena de la polimerasa (PCR), la detección en tiempo real y la interpretación de resultados para automatizar los procesos de detección o cuantificación de los fragmentos de ácido nucleico procedentes de una muestra biológica.
 ", "Country": "XG", "Code": "Intended Use", "Name": "Intended Use" } ] } } ] }

cobas® liat system

<b>cobas</b><sup>®</sup> <b>liat</b> system
Redefinición del Point of Care con diagnóstico por PCR

Diseñada por expertos para optimizar el tamaño, la velocidad y la facilidad de uso, esta solución de PCR compacta ofrece el rendimiento de primera calidad que espera del líder en diagnósticos moleculares y es ideal para su uso en ubicaciones satélite y de Point of Care.

El innovador sistema cobas® Liat® ofrece resultados de PCR precisos y fiables directamente en el Point of Care, lo que garantiza que los pacientes y los clínicos obtengan las respuestas que necesitan en 20 minutos o menos, para respaldar el triaje y la gestión de los pacientes en servicios de urgencias, centros de atención de urgencias, hospitales, clínicas médicas, clínicas farmacéuticas y ubicaciones satélite.

Explora la magia del sistema


El sistema  cobas®  Liat®  automatiza totalmente el proceso de PCR, permitiendo el análisis rápido y preciso de muestras individuales.


El tubo de ensayo del sistema cobas® Liat®

 

Cada tubo de ensayo cobas® Liat® contiene un conjunto de reactivos químicos que copian y amplifican las secuencias de ADN o ARN que son exclusivas de una enfermedad infecciosa concreta.

360 Logo Arrastra la imagen para rotarla
360 degree images list

El analizador cobas® Liat®

 

El analizador de sobremesa pequeño está protegido por una amplia gama de medidas de control de instrumentos y automatiza todos los procesos de análisis de ácidos nucleicos.

Flujos de trabajo de PCR en el Point-of-care simplificados

 Sensible, específico y fácil de usar  

El sistema PCR cobas® Liat® ofrece resultados definitivos mediante una manipulación sencilla e intuitiva por parte del usuario, para que el proceso desde la preparación de la muestra hasta los resultados pueda realizarse sin necesidad de interpretación por parte del operador.

Imagen de muestra

Muestra

Añade la muestra del paciente al tubo de ensayo con la pipeta de transferencia suministrada.

Escanear

Escanear
Coloca el tubo de ensayo debajo del lector de códigos de barras integrado.

iniciar

Iniciar

Introduce el tubo de ensayo en el analizador cobas® Liat®.

Empieza ya tu experiencia con la próxima generación de diagnósticos PCR en el Point of Care
  • Diseño pequeño y compacto para adaptarse a cualquier clínica, centro de urgencias o ubicación satélite

  • Resultados rápidos en 20 minutos* para respaldar las decisiones de tratamiento reactivas

  • Flujo de trabajo totalmente automatizado y conectado para una gestión eficiente de dispositivos y operadores

  • Interfaz de usuario intuitiva con resultados fáciles de interpretar

    *Los tiempos de obtención varían según el ensayo.

Explora nuestro menú de ensayos del sistema cobas® Liat®

Imagen de muestra

Muestra

Añade la muestra del paciente al tubo de ensayo con la pipeta de transferencia suministrada.

Escanear

Escanear
Coloca el tubo de ensayo debajo del lector de códigos de barras integrado.

iniciar

Iniciar

Introduce el tubo de ensayo en el analizador cobas® Liat®.

Empieza ya tu experiencia con la próxima generación de diagnósticos PCR en el Point of Care
  • Diseño pequeño y compacto para adaptarse a cualquier clínica, centro de urgencias o ubicación satélite

  • Resultados rápidos en 20 minutos* para respaldar las decisiones de tratamiento reactivas

  • Flujo de trabajo totalmente automatizado y conectado para una gestión eficiente de dispositivos y operadores

  • Interfaz de usuario intuitiva con resultados fáciles de interpretar

    *Los tiempos de obtención varían según el ensayo.

Explora nuestro menú de ensayos del sistema cobas® Liat®

chicas jóvenes con diagnóstico de gripe

Realiza la prueba. No la ignores.

Respiratorias

Infecciones de las vías respiratorias

La presentación clínica inespecífica de las infecciones respiratorias plantea un desafío considerable para el diagnóstico diferencial de patógenos. ¿Qué impacto puede tener un diagnóstico oportuno y preciso en el tratamiento del paciente?

Más información
Infecciones asociadas a la atención sanitaria

Infecciones asociadas a la asistencia sanitaria (IAAS)

Desde estancias hospitalarias prolongadas hasta la creación de una discapacidad a largo plazo, las infecciones asociadas a la asistencia sanitaria suponen una enorme carga económica para los sistemas sanitarios.

Más información
Resistencia antimicrobiana

Resistencia a los antibióticos y pruebas diagnósticas

A medida que la humanidad continúa su uso generalizado de antibióticos, la resistencia antimicrobiana seguirá suponiendo una amenaza para el sistema sanitario global.

Más información
Rendimiento, conectividad, confianza

El sistema cobas® Liat® coordina la conectividad y el rendimiento con los protocolos compatibles con LIS y POCT1. Comunica los resultados e integra todos los dispositivos de pruebas en el Point of Care con un sistema de gestión de datos central.

 

● Centraliza el control y la gestión de todos los operadores

● Aplica de forma remota las validaciones de lotes de pruebas de CC aprobadas a todos los dispositivos conectados

● Configura y supervisa fácilmente el estado de todos los dispositivos desde un único punto de acceso

Diseñado para una experiencia a prueba de fallos


El sistema cobas® Liat® es un sistema totalmente cerrado que reduce el riesgo de contaminación cruzada a la vez que preserva la integridad de las muestras.

protección de usuario cobas Liat

Seguridad del usuario:


Inicio de sesión seguro con códigos de acceso individuales para garantizar la privacidad de los datos

 

Control de calidad:


Control interno preempaquetado en cada ensayo y reconocimiento automatizado de lotes de reactivos

Monitorización en tiempo real:


Sistema integral de diagnóstico de errores

 

Detección de volumen:


Controla la entrada para garantizar que se utiliza suficiente muestra

sistema cobas Liat de detección de volumen
interpretación de datos automatizada

Interpretación de datos automatizada:


Análisis automático, interpretación e informes de resultados sin intervención del operador

 

Verificación del paciente:


Garantiza que el paciente adecuado esté asociado a la muestra correcta cuando los analizadores están conectados al sistema de información de la institución

Conecta tu Point of Care con la solución cobas® infinity POC.
Explorar

Resumen

Pedidos

Documentos técnicos

error errorMessage
Se ha producido un problema al cargar esta sección.
Vuelve a cargar esta página o inténtalo de nuevo más tarde.