Article

TSIX diagnostic study: Establishing a new global standard in ACS care

Published on 1 okt., 2026 | 5 min read
Global TSIX study validating a high sensitivity troponin assay across diverse populations for cardiovascular research

Key takeaways

  • The TSIX study program sets a new global benchmark for the validation of high-sensitivity cardiac troponin testing

  • Driven by robust studies including REF-TSIX and PERFORM-TSIX, this program evaluates a new high-sensitivity Troponin T assay with a rigorous design across broad, diverse populations to deliver globally reliable clinical evidence

  • Conducted in real-world emergency settings, the PERFORM-TSIX study establishes a robust foundation for the diagnosis and triage of patients with suspected acute myocardial infarction (AMI)

  • In addition, the assay is intended as an aid for early discharge and outpatient management of patients suspected of AMI, and for risk stratification of patients presenting with suspected Acute Coronary Syndrome (ACS)

The TSIX Study: Setting a new standard of ACS care

Chest pain is a top reason for emergency care visits, causing patient anxiety whilst putting pressure on healthcare services.1,2 Only one in ten patients with symptoms is actually having a heart attack.2 With frequent overcrowding in emergency departments globally, quickly and reliably identifying or ruling out AMI is crucial for patient outcomes.3

While high-sensitivity troponin assays are the gold standard for diagnosis, challenges persist, including inconsistent interpretation of low-level values and the need for more globally validated data.4,5 Addressing these challenges requires a solid scientific foundation.

What is the TSIX study program?

The TSIX study program is a comprehensive global diagnostic study and the largest of its kind for a high-sensitivity troponin assay, setting a new standard in ACS care.1,6 The program's robust approach and rigorous methodology make its findings highly relevant for clinical practice worldwide.

Learn more about the TSIX program

Establishing global 99th percentile cut-off values with REF-TSIX

A core milestone of the TSIX study program is establishing precise, universally applicable 99th percentile URLs for the detection of myocardial injury with the new high-sensitivity Troponin T assay.

Through the global REF-TSIX reference study, a rigorous protocol was applied to a broad, diverse cohort of rigorously screened healthy individuals worldwide applying the stringent criteria of the IFCC. 6,7

A globe icon, illustrating the global study to validate one diagnostic cutoff of Elecsys cardiac Troponin T hs Gen 6

4,147 study subjects

An icon of a couple illustrating the one overall diagnostic cutoff of Elecsys cardiac Troponin T  T hs Gen 6 assay

Overall

27 ng/L

An icon of a woman’s head illustrating the female diagnostic cutoff of Elecsys cardiac Troponin T  T hs Gen 6 assay

Female

18 ng/L

An icon of a man’s head illustrating the male diagnostic cutoff of Elecsys cardiac Troponin T  T hs Gen 6 assay

Male

32 ng/L

Determining clinical performance across different hospital settings and regions with PERFORM-TSIX

The PERFORM-TSIX study validated the clinical performance of new URLs and the assay's performance within the European Society of Cardiology (ESC) recommended rapid diagnostic algorithms in a real-world setting. Enrolling over 5,600 patients across 50 clinical centers worldwide, the study demonstrated the assay's high effectiveness in identifying heart attacks and high safety in ruling them out.8,9

The ESC 0/1h and 0/2h algorithms using the new generation of high sensitivity Troponin T assay

Key clinical highlights:8,9

  • Standardized pathways: Establishes optimized cutoff values based on the ESC 0/1-h and 0/2-h pathways for rapid management of suspected NSTEMI (Non-STE-Myocardial Infarction)

  • High efficiency: Successfully triages approximately 70% of patients with suspected AMI within 1 to 2 hours

  • Rapid & safe triage: Demonstrates high diagnostic efficacy for AMI rule-in alongside validated safety for early rule-out and patient discharge

While these algorithms are excellent to triage patients to high risk (rule-in) and low risk (rule-out), a final diagnosis should be made according to the 5th Universal Definition of Myocardial Infarction.10

Learn more about the PERFORM-TSIX study

A robust scientific foundation for diagnostic confidence

The rigorous methodology of the TSIX program ensures that the assay provides high analytical sensitivity and is globally applicable and  reliable. The program's design validates the core pillars of the high-sensitivity Troponin T assay: precision, robustness, and global validation.11,12

In addition, the findings are used to extend the claims extension beyond diagnosis of acute myocardial infarction to include:

  • Aid in Diagnosis: aid in the differential diagnosis of acute coronary syndrome to identify necrosis, e.g. AMI.
  • Safe early Discharge: an aid for early discharge and outpatient management for patients suspected of ACS.
  • Risk Stratification: The test is further indicated for the risk stratification of patients presenting with suspected acute coronary syndrome.

The comprehensive data from the TSIX study program gives clinicians the confidence to interpret high-sensitivity Troponin T levels to optimize emergency triage, may accelerate immediate therapy for high-risk patients suspected of ACS while facilitating safe, early discharge for low-risk individuals.

The future of ACS care

The TSIX study provides robust evidence for future innovations, such as new ACS biomarkers, devices, and algorithms, aiming to improve outcomes and efficiency in the emergency department.

Roche stays at the forefront of extensive clinical validation, and we will continue to fund the most impactful studies and generate evidence that seeks to enhance ACS care further.

Contributors

Roche-Hochhaus - Ansicht Südwest - Burckhardt Partner AG - 2011 - Rotkreuz

Roche Diagnostics

Roche Diagnostics is a division of Roche, developing and integrating diagnostic solutions that address today’s healthcare challenges while anticipating tomorrow’s needs. In more than 100 countries, we provide one of the industry’s most comprehensive in vitro diagnostics portfolios spanning molecular diagnostics, clinical chemistry and immunoassays, tissue diagnostics, Point of Care testing, patient self-testing, next-generation sequencing, laboratory automation and IT, as well as digital health and decision-support solutions.

Our articles are authored by Roche Diagnostics subject matter experts, drawing on collective expertise across multiple disciplines to provide reliable insights for healthcare professionals worldwide.

Explore articles from our community

Contact us

Do you have questions about our products or services? We’re here to help. Contact a Roche representative in your region.

References

  1. Audrey J, et al. Most Frequent Reasons for Emergency Department Visits, 2018. Agency for Healthcare Research and Quality [Internet; cited 2026 Sep 18]. Available from: https://hcup-us.ahrq.gov/reports/statbriefs/sb286-ED-Frequent-Conditions-2018.jsp.
  2. Fanaroff AC, et al. Does this patient with chest pain have acute coronary syndrome?: the rational clinical examination systematic review. JAMA. 2015;314:1955–65.
  3. Velt KB, et al. Emergency department overcrowding: a survey among European neurotrauma centres. Emerg Med J. 2018;35:447–8.
  4. European Society of Cardiology. 2023 ESC guidelines for the management of acute coronary syndromes. Eur Heart J. 2023.
  5. McEvoy J, et al. Myocardial injury thresholds for four high-sensitivity troponin assays in U.S. adults. J Am Coll Cardiol. 2023;81:2028–39.
  6. Daniels LB, et al. Establishing reference values in healthy participants for a next generation cardiac troponin T high-sensitivity assay – the REF-TSIX global reference study. Clin Chem. 2026;72:488–502.
  7. Aakre KM, et al. Analytical considerations in deriving 99th percentile upper reference limits for high-sensitivity cardiac troponin assays: educational recommendations from the IFCC committee on clinical application of cardiac bio-markers. Clin Chem. 2022;68:1022–30.
  8. ClinicalTrials.gov. A study of Elecsys® Troponin T hs Gen 6 in participants with symptoms of acute coronary syndrome (PERFORM-TSIX) [Internet; cited 2026 Sep 18]. Available from: https://clinicaltrials.gov/study/NCT06734117?term=NCT06734117&rank=1.
  9. Daniels LB, et al. Clinical performance of the next generation cardiac Troponin T high-sensitivity Gen 6 assay: an international study. Manuscript in preparation.
  10. Mills N, et al. Fifth universal definition of myocardial infarction. Eur Heart J. 2026;0:1–48.
  11. F. Hoffmann-La Roche Ltd. Elecsys® Troponin T hs Gen 6. Method sheet. (v3.0). 2026.
  12. Knoll M, et al. Analytical performance of a Troponin T high-sensitivity Gen 6 assay. Poster P0380 presented at EuroMedLab; May 2025.