cobas® connection modules allow the connection of the standalone automation systems, cobas® p 512 and cobas® p 612, to analytics and post-analytics through a fast transportation system.

cobas connection modules (ccm)

Fast and simply efficient

cobas® connection modules (CCM), powered by navify® Lab Operations allows labs of all sizes to reach a new level of productivity. Streamline and optimize laboratory processes with an automation solution designed to work together to deliver samples to multidisciplinary targets at speeds of up to 10,000 samples per hour.

Benefits at a glance

Benefits at a glance

Take advantage of the huge flexibility of the standalone automation concept, while adding predictability of time to results by integrating solutions with cobas connection modules.

Boost productivity by also utilizing CCM to sort non-connected work areas:

  • Flexible and freely definable sorting areas
  • Sort into various racks supplied from Roche and other vendors
  • First pass and recursive workflow
  • Archiving of samples

CCM gives you the option to connect multiple laboratory disciplines in a seamless integrated solution:

  • Serum Work Area
  • Hematology
  • Coagulation
  • Urinalysis
  • Molecular Diagnostics
  • Post-analytics

Streamline workflows and drive better patient outcomes with proven safety and efficiency with a system that is cross-contamination compliant for NAT testing.

Comprehensive inspection of samples at an early stage, optimizing the lab workflow and ensuring the best use of time and resources, including:

  • Tube type identification
  • Liquid Level Detection 
  • Spin status detection, which identifies whether blood samples have been centrifuged or not 
  • Sample quality check, which enables detection of normal, hemolytic, lipemic and icteric samples

Easy on-site solution expansion as you need it.

Use left and right arrow keys to scroll between the tabs

Overview

Ordering Information

cobas® connection modules (CCM) Technical Specifications

View Full Table

cobas® connection modules (CCM) Technical Specifications

System description cobas® connection modules (CCM) enables the connection of the cobas p 512 and cobas p612 pre-analytical systems to the following pre-analytical, analytical and post-analytical instruments:
  • cobas® 8000 modular analyzer series
  • cobas® 6000 modular analyzer series
  • cobas® 6800 system
  • cobas® 8800 system
  • Sysmex HST
  • Sysmex XN-9000
  • STAGO STA-R Evolution
  • STAGO STA R Max
  • cobas p 501 post-analytical unit
  • cobas p 701 post-analytical unit
Sample carriers RD Hitachi 5-position racks and Sysmex 10- position racks
Tube types Supports established tubes for hematology, coagulation, serum, cobas PCR Media tubes, plasma and urine manufactured by BD, Sarstedt, Kabe, Greiner, Terumo and other tube vendors
  • Diameter 13–16 mm
  • Length 75–110 mm (including caps)
CCM units** Specifications Throughput/unit Catalog number
Conveyor 1 Unit (0,5m)
  • Width: 500 mm (19.68")
  • Depth: 185 mm (7.28")
  • Height: 930 mm (36.61")
  • Weight: approx. 30 kg (66 lbs)
Up to 2000 tubes/hour 06770568001
Conveyor 2 Unit (1m)
  • Width: 1000 mm (39.37")
  • Depth: 185 mm (7.28")
  • Height: 930 mm (36.61")
  • Weight: approx. 40 kg (88 lbs)
Up to 2000 tubes/hour 06770576001
Turn Unit
  • Width: 310 mm (12.20")
  • Depth: 310 mm (12.20")
  • Height: 930 mm (36.61")
  • Weight: approx. 20 kg (44 lbs)
Up to 2000 tubes/hour 06770592001
Bi-directional Connection Unit
  • Width: 620 mm (24.41")
  • Depth: 820 mm (32.28")
  • Height: 930 mm (36.61")
  • Weight: approx. 105 kg (238 lbs)
Up to 2000 tubes/hour 07276001001
Output Unit
  • Width: 800 mm (31.50")
  • Depth: 850 mm (33.46")
  • Height: 1100mm (43.31")
  • Weight: approx. 190 kg (418)
  • Capacity/unit: 675 tubes
Up to 2000 tubes/hour 07667574001
**Additional parts are required depending on system configuration. For information on all units needed for a specific configuration please consult a Roche representative.

Please note that not all versions are distributed in all countries. For further details contact your local affiliate.

error errorMessage
Sorry, we couldn't find the content you are looking for
Please try again later

Related products

Contact us

Do you have questions about this product or service? We’re here to help. Fill out the form to contact a Roche representative.