{ "ProductData": { "ID": "INS_6818", "ProductType": "Instrument", "BrandName": "cobas® infinity POC", "ProductNameAddition": "cobas® infinity POC is an integrated web based application with open connectivity that helps manage Point of Care Testing from a single location.", "RegulatoryDisclaimer1": "For general laboratory use.", "DisclaimerGroup1": "GPR", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "cobas infinity POC" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/cobas_infinity_POC.jpg", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "1", "StructureSystemName": "GPCH", "NodeID": "10184", "StructureNodeStatus": "", "NodeName": "" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeID": "60-000-00", "StructureNodeStatus": "valid", "NodeName": "Electronic Services" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeID": "110", "StructureNodeStatus": "valid", "NodeName": "cobas" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeID": "110-00", "StructureNodeStatus": "valid", "NodeName": "Point of Care Testing" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeID": "051", "StructureNodeStatus": "valid", "NodeName": "Digital solutions" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeID": "130", "StructureNodeStatus": "valid", "NodeName": "Lab automation" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeID": "999-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeID": "11-00-00", "StructureNodeStatus": "valid", "NodeName": "Critical Care" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeID": "99-00-00", "StructureNodeStatus": "invalid", "NodeName": "" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "09328521001", "MaterialDescription": "inf POC Intersys lic transition support", "RegisteredProductName": "inf POC Intersys lic transition support", "GTIN": "07613336192726", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "09185879001", "MaterialDescription": "inf POC Intersystems lic L (1201-2000)", "RegisteredProductName": "inf POC Intersystems lic L (1201-2000)", "GTIN": "07613336178751", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "undefined", "OrderInformation": "" }, { "MaterialNum": "09220763001", "MaterialDescription": "cobas infinity POC remote access - 1.x", "RegisteredProductName": "cobas® infinity POC", "GTIN": "07613336192429", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "undefined", "OrderInformation": "" }, { "MaterialNum": "09185836001", "MaterialDescription": "inf POC Intersystems lic XS (1-150)", "RegisteredProductName": "inf POC Intersystems lic XS (1-150)", "GTIN": "07613336178720", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "undefined", "OrderInformation": "" }, { "MaterialNum": "09159053001", "MaterialDescription": "cobas infinity POC core license - 2.x", "RegisteredProductName": "cobas® infinity POC", "GTIN": "07613336175385", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "09185844001", "MaterialDescription": "inf POC Intersystems lic S (151-600)", "RegisteredProductName": "inf POC Intersystems lic S (151-600)", "GTIN": "07613336178737", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "undefined", "OrderInformation": "" }, { "MaterialNum": "09185852001", "MaterialDescription": "inf POC Intersystems lic M (601-1200)", "RegisteredProductName": "inf POC Intersystems lic M (601-1200)", "GTIN": "07613336178744", "ProductCategoryText": "Electronic Services", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "undefined", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Name": "Intended Use", "Value": "cobas® infinity POC is a data management software system providing governance and connectivity to Point of Care devices centralizing the management of professional Point of Care testing service.

cobas® infinity POC supports workflow configuration of connected Point of Care devices, management of device related data, operators, test orders and patient demographic data including results.

These data are automatically received, stored and evaluated based on user-configurable criteria and sent to the customers Health Information Systems.

The professional personnel can review and audit these data and perform other data management functions.
This product is not intended for the diagnosis, screening, monitoring or treatment of patients.

It is important to note that cobas® infinity POC is not intended to be used for patient diagnosis or treatment decisions. Such decisions should be made on the basis of the results displayed on the POC instrument.", "Language": "en", "Country": "XG", "Code": "Intended Use" } ] } } ] }

cobas® infinity POC solution

Centralizing decentralized patient care through innovation.

GPR For general laboratory use.
cobas infinity POC solution
Elevating care, decreasing complexity

Point of Care Product Portfolio

Point-of-care (POC) solutions help healthcare professionals do more with less, providing much-needed insights when and where it matters most

Decentralizing care leads to increased complexity if not sufficiently handled. Today, cobas® infinity POC is enabling the centralized management of your entire POC environment from a single point of access. With open connectivity that links POC devices from multiple vendors and the capacity for LIS/EMR integration, complexity can be replaced by a renewed focus on patient care.

Advance your connectivity the smart way.
Request more information
optimize productivity

Optimize productivity

Integrate both Roche instruments and widely used non-Roche devices as well as key information management systems to realize new efficiencies and easily manage devices, no matter where they are.

  • Integrate with external learning management systems and eliminate manual updates
  • Create or modify operator accounts quickly and easily
  • Easily manage operator certifications with automatic alerts
  • Connect the full Roche POC portfolio, including Accu-Chek® Inform II, CoaguChek® XS Plus, CoaguChek® XS Pro, Urisys 1100®, the cobas® Liat® PCR System, and widely-used non-Roche devices
  • Seamlessly transfer results to most industry-leading EMR and LIS to drive well-informed clinical decisions.
  • Accomplish more tasks, on the go with an interaction-based user experience optimized to work on mobile devices
  • Automated recertification with available Observed Test Sequence* to streamline competency

*Available on the Accu-Chek Inform II, CoaguChek XS Plus and CoaguChek XS Pro

Quality assurance

With the cobas® infinity POC solution, ensuring quality, accuracy, and safety is easier than ever.

  • Enhanced QC review allows you to monitor your solutions on the go
  • Streamlined reporting identifies possible areas of improvement with a complete audit trail
  • Customizable alerts notify you immediately about issues that require your attention
quality assurance
easy secure onboarding

Easy and secure onboarding

Optimize the use of staff time by streamlining user training and management.

  • Partner with you to configure cobas® infinity POC alerts and settings to your needs
  • Help navigate a successful and on time implementation through Roche-provided project management
  • Access on-demand online training through the Roche Diagnostics University
  • Cybersecurity and data privacy woven into every step from development to remote implementation and customer service, plus a dedicated team of cybersecurity experts to support your needs.

 

A Total POC Solution from Roche

cobas® infinity POC was developed from the ground up with system integration in mind. Designed to seamlessly integrate with our instruments, this total solution allows you to unlocks new benefits for your organization and the patients you serve.

Accu-Chek® Inform II Total Solution

Save time, think several steps ahead and make more informed clinical decisions with the Accu-Chek® Inform II Total Solution. Discover how you can empower your teams with a connected digital diagnostic system.

cobas® Liat® Total Solution

The cobas® Liat® system makes it easy to connect your entire point-of-care environment. Learn how to manage operators, connect your analyzer, view data and results, and valid assay lots to get the most out of your system.

Utilizing data for a more personalized approach to healthcare

We are bringing healthcare thinking to technology.

cobas® infinity POC is a core solution within the Roche Digital Diagnostics portfolio. This suite of advanced digital solutions combes innovative thinking, data analytics, and deep healthcare expertise to enable improved operations, financial performance and patient management.

By optimizing the use of healthcare data, we can better meet changing demands and improve care from the POC to the laboratory and beyond.
Get more information on how we are bringing healthcare thinking to technology today
Contact us

Overview

Ordering Information

Technical Documents

cobas® infinity POC server specifications*

View Full Table

cobas® infinity POC server specifications*

 

Server Platform

Customer provided hardware or virtual machine.

HTTPS Certificate

Customer IT needs to create a HTTPS certificate. This needs added to server’s IIS Server Certificate Web Hosting cert store. Certificate must be trusted by customer’s user PCs.

 

Web Server Software

Microsoft Internet Information Server (IIS)

Database Software

Intersystems Cache (provided with cobas® infinity POC)

HW Architecture/Operating System

64-bit Microsoft Windows Server 2012 R2 or Microsoft Windows Server 2016

Server Framework

Windows Server 2012 R2 with .NET 3.5(4) and 4.5.2(5) and Windows Server 2016 with .NET 3.5 and 4.6

Number of CPU Cores

8

RAM

32 GB

Hard Drive 1 (System)

100 GB

Hard Drive 2 (Database)

300 GB - 1 TB

Hard Drive 3 (Backups and Journals) 300 GB - 1 TB
Number of Network Adaptors 2 NICs (Second NIC for shadowing)
*These minimum specifications provide general guidance. Roche recommends technical discussions for complex installations. Failure to meet minimum specifications may impact application performance.
cobas® infinity POC capabilities

Instrument Management

  • Instrument settings can be configured in the data manager and uploaded to managed instruments (Instrument must support configuration from the data manager)
  • Instrument firmware update via Data Management (Roche instruments only)
  • Customize access to patient testing based on operator certification status (Instrument must support operator lockout)
  • Data manager can configure automatic operator time out settings on the instrument (Instrument must support operator lockout from the data manager)
  • Configure the instrument to lock and unlock based on QC control status (Instrument must support QC lockout from the data manager)
  • Request POC instrument synchronization from Data Manager
  • Send patient lists to instruments (Instrument must support patient lists sent from the data manager)

 

Operator Management

  • Ability to handle thousands of operators with multiple roles, security profiles, and location assignments
  • User accounts can be created or modified in batches through and import process

 

Operator Certification

  • Certification management with automatic recertification
  • Ability to perform and record direct observation using Observed Testing Sequence (OTS) on the instrument (Supported from the Accu-Chek Inform II, CoaguChek XS Plus, and CoaguChek XS Pro)
  • Integration with external LMS systems with the addition of the LMS Integration module
  • Automatic On-instrument notification of expiring certifications and certification tasks due (Instrument must support this capability)
  • Automatic e-mail notification to designated operator managers

 

Material Management

  • Data Manager provides warnings and can send e-mails on expired materials to POCC
  • Assign materials to specific instruments by location
  • Distinguish which QC lot was run on a specific test material lot
  • Download approved material information from Data Manager to instrument (Instrument must support material information download from data manager)

 

Quality Control (QC)

  • Manual and Automatic QC result management
  • QC reporting and data export
  • Proficiency result tracking
  • Download approved QC material information from Data Manager to instrument (Instrument must support QC material information download from data manager)

 

Result Management

  • Ability to define criteria for automatic result validation
  • Custom comments can be defined in the data manager and downloaded to the instrument for use on specified tests
  • Test errors, flags, alarms, comments, and instrument ID can be transmitted to the LIS

 

Reports

  • Built-in predefined reports
  • Export data from any screen

 

Connectivity

  • Connect to Roche and non-Roche instruments
    • Accu-Chek® Inform II System
    • cobas® Liat® PCR System
    • CoaguChek® XS Plus and XS Pro
    • Urisys 1100
    • cobas b 221
    • Abbott i-STAT® 1 System*
    • Alere Afinion AS100
    • HemoCue® 201 DM Glu, 201 DM Glu RT, and  201 DM Hb
    • Hemochron Signature Elite
    • Siemens CLINITEK Status® and Status® Connect
    • Siemens DCA Vantage
    • IL GEM Premier 3000 
    • IL GEM Premier 4000 
    • Medtronic ACT Plus 
    • Philips Bilichek Module
    • Piccolo Xpress Module
    • Radiometer 700 Series
    • Radiometer ABL 80 & 80 Flex
    • Radiometer ABL800 
    • Radiometer ABL 90
    • Siemens Rapidpoint 400 
    • Siemens Rapidpoint 500 
    • Sysmex pocH 100i 
COBAS, ACCU-CHEK, ACCU-CHEK INFORM and COAGUCHEK are trademarks of Roche. All other product names and trademarks are the property of their respective owners. Device functionality varies by manufacturer.
All other products listed in cobas infinity POC documents are not available for use within the US market  
*Additional Abbott i-STAT® DE server required
  • Interface to multiple HIS/LIS systems
  • Configurable ADT mapping

 

User Interface

  • Completely re-imagined user interface
  • Web-based interface
  • Mobile interface for select tasks including operator and device management

 

System Management

  • Multisite capability
  • Complete audit trail for the entire flow of communication from instrument through middleware to LIS
error errorMessage