{ "ProductData": { "ID": "INS_6758", "ProductType": "Instrument", "BrandName": "VENTANA DP 600 slide scanner", "ProductNameAddition": "", "RegulatoryDisclaimer1": "See country-specific product labeling for regulatory status.", "DisclaimerGroup1": "Country Specific Labeling", "RegulatoryDisclaimer2": "", "DisclaimerGroup2": null, "RegulatoryDisclaimer3": "", "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "VENTANA DP 600 slide scanner" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Ventana_DP600_Slide_Scanner_image.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "1", "StructureSystemName": "GPCH", "StructureNodeStatus": "", "NodeName": "", "NodeID": "10118" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "VENTANA", "NodeID": "410" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Pathology Lab", "NodeID": "080-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "Whole Slide Imaging", "NodeID": "200-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Digital pathology", "NodeID": "012" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Digital solutions", "NodeID": "051" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "09311378001", "MaterialDescription": "VENTANA DP 600 slide scanner RUO", "RegisteredProductName": "VENTANA DP 600 slide scanner (RUO)", "GTIN": "", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "en", "Value": "VENTANA DP 600 slide scanner is a computer and imaging based device that has the capability to scan stained tissue specimens on glass slides, and digitize, compress, store, retrieve, and view digitized images of tissue slide specimens on glass slides.

When used with a Roche Image Management Software (or System), VENTANA DP 600 slide scanner is intended to automatically scan stained tissue specimens on glass slides and provide automated digital slide creation, management, and viewing capabilities to aid users with examination of human tissue specimens.
 ", "Country": "XG", "Code": "Intended Use", "Name": "Intended Use" } ] } } ] }

VENTANA DP 600 slide scanner

VENTANA DP 600 slide scanner
Do you have any questions?
Contact us
Enabling full digitization of your pathology laboratory

The VENTANA DP 600 slide scanner is a significant addition to the Roche Digital Pathology portfolio as it will enable pathology laboratories to perform high volume and high quality scanning necessary for full digitization of their pathology workflow with Roche as the partner of choice.

 

High-capacity scanner maximizes walkaway time

Lean workflow through continuous loading of trays

 

Ease of use and workflow flexibility

Intuitive design and minimalistic user-interface streamlines workflow

 

High image quality and reliable performance

Dynamic focus technology and innovative optics

 

VENTANA DP 600 slide scanner features

 

  • High-speed scanning: Scans at 20x magnification in ~36 seconds and at 40x magnification in ~73 seconds (15mm x 15mm areas of interest (AOIs))
  • High capacity: 240-slide capacity, 40 trays of 6 single slides
  • No slide handling: Tray-based system eliminates slide handling errors, such as breakage and loss of slides, for improved reliability
  • High-quality images: Dynamic focus technology tracks tissue depth in real-time and utilizes the data for high-resolution images
  • DICOM (Digital Imaging and Communications in Medicine) compatibility: Enable interoperability with true DICOM files through LIS connectivity
  • Color management: International Color Consortium (ICC) color profile applied to every scanned image
  • Calibration: Automatic white balance calibration to ensure consistent image quality
  • Continuous load: Lean workflow through continuous tray loading to keep up with slide volume without interrupting scanning
  • Color coded light notifications: LED indicators to visually inform user of scanner and slide status
  • Usage report: Access to statistics on scanner performance and usage
  • STAT: STAT workflow for research such as frozen sections
  • File formats: BIF, TIF and DICOM

* VENTANA DP 200 slide scanner and uPath algorithms are for Research Use Only. Not for use in diagnostic procedures.