The long-life, maintenance-free electrodes are at the heart of the 9180 Electrolyte Analyzer and form a totally visible sample chamber ensuring high precision and reliability.
The 9180 Electrolyte Analyzer is a very low maintenance analyzer. Long-life, no maintenance electrodes, single-pump and simple fluidic path design reduces routine maintenance to a minimum. Reagents and waste are sealed into a single SnapPak eliminating the need to change multiple containers or handle waste.
The 9180 Electrolyte Analyzer incorporates a Quality Control program, which stores up to 35 values of each of three control levels and automatically flags out-of-range results. QC statistics, including a running mean value, standard deviation and coefficient of variation, can be printed out on all three QC levels at any time, providing the user with an immediate trend analysis of instrument performance.
ISETROL, a precisely formulated control that needs no refrigeration, is the product of choice to monitor the performance of the 9180 Electrolyte Analyzer.
Please submit your information in the following form to be contacted by a Roche representative with more details about the 9180 Electrolyte Analyzer.
Electrolyte results obtained from 95 μl of whole blood, serum, plasma, acetate, bicarbonate dialysate or bicarbonate dialysate, or pre-diluted urine. All reagents, as well as waste, are sealed in the convenient SnapPak container. The Electrolyte Analyzer monitors the amount of remaining reagent and prompts the user to insert a fresh SnapPak container when required. A built-in sensor ensures that SnapPak has been correctly installed.
The analyzer is fully automatic. A two-point calibration is carried out every four hours and a one-point calibration with each test, ensuring precision and conformity to even the most stringent regulatory requirements.
The 9180 Electrolyte Analyzer gives you a choice of seven different, interchangeable electrolyte configurations to fit your immediate and future testing needs. To change the configuration, all you have to do is substitute the electrode and recalibrate. There is no need to change reagents or replace any tubing.
In the United States, the 9180 Electrolyte Analyzer can be configured in the following ways:
In the United States, the 9180 Electrolyte Analyzer can be configured in the following ways:
Na+, K+ | Na+, K+, Cl– |
Na+, Li+ | Na+, K+, Li+ |
Li+ | Na+, Cl– |
Na+ | Â |
Electrodes | ||
---|---|---|
Sodium Sensor | Na+ | ion selective, flow-through, glass capillary electrode |
Potassium Sensor | K+ | ion selective, flow-through, liquid membrane electrode |
Chloride Sensor | CI– |
ion selective, flow-through, liquid membrane electrode |
Lithium Sensor | Li+ | ion selective, flow-through, liquid membrane electrode |
Reference System | 25 reagent slots with a maximum of 18 on-board assays |
open liquid junction, flow-through electrode |
Measuring Range (in mmol/L) | |||
---|---|---|---|
Whole Blood, Serum, Plasma, QC-Material | Na+ K+ CI– Li+ |
resolution 0.1 mmol/L resolution 0.01 mmol/L resolution 0.1 mmol/L resolution 0.001 mmol/L |
range 40–205 mmol/L range 1.5–15 mmol/L range 50–200 mmol/L range 0.1–6.0 mmol/L |
Dialysate | Na+ K+ CI– |
resolution 0.1 mmol/L resolution 0.01 mmol/L resolution 0.1 mmol/L |
range 40–205 mmol/L range 0.8–15.0 mmol/L range 50–200 mmol/L |
Urine | Na+ |
resolution 1.0 mmol/L resolution 0.1 mmol/L resolution 1.0 mmol/L |
range 1–300 mmol/L range 4.5–120 mmol/L range 1–300 mmol/L |