{ "ProductData": { "ID": "INS_754", "ProductType": "Instrument", "BrandName": "Accutrend® Plus system", "ProductNameAddition": "", "RegulatoryDisclaimer1": "For in vitro diagnostic use.", "DisclaimerGroup1": "IVD", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "Accutrend Plus" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Accutrend-Plus-system.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "1", "StructureSystemName": "GPCH", "NodeID": "1042", "StructureNodeStatus": "Active", "NodeName": "Accutrend Plus" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeID": "020", "StructureNodeStatus": "Active", "NodeName": "Accutrend" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeID": "10-000-00", "StructureNodeStatus": "Active", "NodeName": "Analyzer Instruments and Systems" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeID": "100-00", "StructureNodeStatus": "Active", "NodeName": "Patient Self Testing" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeID": "110-00", "StructureNodeStatus": "Active", "NodeName": "Point of Care Testing" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeID": "020", "StructureNodeStatus": "Active", "NodeName": "Clinical Chemistry" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeID": "999-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeID": "27-00-00", "StructureNodeStatus": "Active", "NodeName": "Metabolic disease" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "05346754160", "MaterialDescription": "Accutrend Plus Kit mg/dL, EN (USA)", "RegisteredProductName": "Accutrend® Plus system (mg/dl)", "GTIN": "00365702284104", "ProductCategoryText": "Meters", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ { "ProductID": "CPS_001004", "BrandName": "Accutrend® Cholesterol", "ProductNameAddition": "", "ReferenceType": "Reagent", "Classification": [ { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "020", "StructureGroupPath": "Accutrend", "StructureGroupName": "Accutrend", "StructureNodeStatus": "Active" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "20-000-00", "StructureGroupPath": "Assays Reagents and Strips", "StructureGroupName": "Assays Reagents and Strips", "StructureNodeStatus": "Active" }, { "IdentifierofStructureSystem": "Product_Grouping", "NameofStructureSystem": "Product Grouping", "StructureNodeID": "01-0001", "StructureGroupPath": "CPS->Accutrend Cholesterol", "StructureGroupName": "Accutrend Cholesterol", "StructureNodeStatus": "Active" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "110-00", "StructureGroupPath": "Point of Care Testing", "StructureGroupName": "Point of Care Testing", "StructureNodeStatus": "Active" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "100-00", "StructureGroupPath": "Patient Self Testing", "StructureGroupName": "Patient Self Testing", "StructureNodeStatus": "Active" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "020", "StructureGroupPath": "Clinical Chemistry", "StructureGroupName": "Clinical Chemistry", "StructureNodeStatus": "Active" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "Inactive" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "999-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "Inactive" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "Inactive" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "Inactive" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "27-00-00", "StructureGroupPath": "Metabolic disease", "StructureGroupName": "Metabolic disease", "StructureNodeStatus": "Active" } ] } ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Name": "Intended Use", "Value": "The Accutrend Plus instrument is used for quantitative measurement of one blood parameter: Total cholesterol.

The reflectance photometric measurement is performed using test strips specific for this blood parameter. For detailed information about the test, see the package insert of the test strip.", "Language": "en", "Country": "US", "Code": "Intended Use" }, { "Name": "Specification", "Value": "Operating conditions and technical data
 
Temperature range for measurementDependent on test parameter:
- Cholesterol and triglycerides: 18–30°C
- Glucose: 18–32°C
- Lactate: 15–35 °C
Relative humidity10-85 %
Measurement range- Blood glucose: 20–600 mg/dL (1.1–33.3 mmol/L)
- Cholesterol: 150–300 mg/dL (3.88–7.76 mmol/L)
- Triglycerides: 70–600 mg/dL (0.80–6.86 mmol/L)
- Lactate: 0.8–21.7 mmol/L (blood value), 0.7–26 mmol/L (plasma value)
Memory100 measured values, optional with date, time and additional information per test parameter
InterfaceInfrared interface, LED/IREDClass 1
Battery operation4 x AAA 1.5 V alkaline manganese batteries
Number of measurementsMore than 1,000 measurements (with new batteries)
Protection classIII
Dimensions154 x 81 x 30 mm
WeightsApprox. 140 g

Sample material
 
Sample typeFresh capillary blood (for detailed information see package insert)
Sample volumeA free hanging drop of blood
InteractionsSee test strip insert


Storage and transport conditions
 
Temperature range–25°C to +70°C
Relative humidity10 to 85 % (no condensation)
", "Language": "en", "Country": "XG", "Code": "Specification" }, { "Name": "Product Purpose", "Value": "The Accutrend Plus instrument is used for quantitative measurement of one blood parameter: Total cholesterol.

The reflectance photometric measurement is performed using test strips specific for this blood parameter. For detailed information about the test, see the package insert of the test strip.", "Language": "en", "Country": "US", "Code": "Product Purpose" } ] } } ] }

Accutrend® Plus system

Screening for cardiovascular risk factors

IVD For in vitro diagnostic use.
Accutrend® Plus system
The Accutrend Plus system: Total cholesterol result in about three minutes

Cardiovascular disease is the #1 killer in the United States, early CVD risk detection can help to save lives1. The CLIA-waived Accutrend Plus system delivers total cholesterol test results providing immediate, actionable information.

Do you have any questions?
Contact us

Overview

Ordering Information

Technical Documents

Accutrend Plus Meter Specifications

View Full Table

Accutrend Plus Meter Specifications

Specification  
Measuring principle Reflectance (660 nm)
Sample type Fresh capillary blood
Coding Barcode
Size 154 mm x 81 mm x 30 mm
Power supply Four AAA batteries
Battery life > 1000 tests
Memory capacity 100 values for each parameter

Accutrend Test Strip Specifications

View Full Table

Accutrend Test Strip Specifications

Specification Accutrend Cholesterol
Sample volume 15 - 40 µl
Test time for results 180 sec.
Measuring range 150 - 300 mg/dl
Accuracy y = 1.057x - 14.9 
r = 0.920
Precision CV LO = 2.9%, x = 203 
Range 173 - 224 mg/dl
Reference method Hitachi CHOD-PAP
Storage conditions Room temperature
Test strip shelf life from date of manufacturing 18 months

Ordering Information

View Full Table

Ordering Information

Product Catalog Number
Accutrend Plus Meter Kit 05346754160
Accutrend Plus Cholesterol test strips (25/vial) 05213312160
Accutrend Plus Cholesterol controls 05219957001