User Profile
Select your user profile

cobas® 4000 analyzer series

Freedom to realize your lab’s potential

IVD For in vitro diagnostic use.
Product image for cobas® 4000 analyzer series
Freedom to realize your lab’s potential

The cobas® 4000 analyzer series provides suitable solutions for clinical chemistry and immunochemistry testing in low-volume laboratories.

Standardization
Standardization

Drive lab efficient with standard instrumentation, reference ranges, consumables, and usage. 

Reliability
Reliability

Minimize downtime with industry-leading engineering and service.

Rapid TAT
Rapid TAT 

Speed up turnaround time for high volume STAT assays for a new level of fast service. 

Capacity
Capacity

Designed for laboratories processing 25,000 to 500,000 tests per year or 50 to 400 samples per day. 

Would you like to know more about the cobas® 4000?

Please submit your information in the following form to be contacted by a Roche representative with more details about the cobas® 4000.

Form Successfully Submitted!
Thank you for your submission!
text
alt

Overview

Ordering Information

Technical Specifications

cobas c 311 Analyzer

View Full Table

cobas c 311 Analyzer

 

Test throughput
  • 300 photometric tests/hour
  • 450 ISE tests/hour
Number of channels 42 channels and 3 ISEs
Programmable parameters 86 photometric applications, 3 ISE applications, 3 serum indices, 8 calculated results
Sample material Serum/plasma, urine, CSF, WB (HbA1c only)
Sample input/output Disk with 108 positions for samples, calibrators and controls, plus W1 position for ISE cleaning solution, W2 position for ISE activator; user-definable STAT positions
Sample barcode types NW7 (Codabar); Code 39; ITF; Code 128
System interface RS-232C serial interface
Sample database 10,000 results (routine, STAT and QC)
Calibration methods Start-up, re-calibration for photometric assays: Linear, non-linear multi points, 2 point calibration, K-factor. Up to 100 calibrators pre-programmable, storage of up to 180 curves. Preventative calibration of standby cassettes. Two K-factors can be defined for different sample types.
QC methods Individual QC and cumulative QC. Up to 100 controls pre-programmable/Preventative QC after calibration of standby cobas c packs/Auto QC (without operator intervention).
Electrical requirements 115 Volts AC; Frequency 60 Hz +/- 0.5%
Water requirements Water Type: bacteria-free, deionized water
Water consumption ~ 12 L/hr during operation
Operating conditions Ambient room temperature of 15 to 32°C; relative humidity 30 to 85% non-condensing
Physical dimensions
  • Depth: 34 in (86.4 cm)
  • Height closed: 50 in (127 cm)
  • Height open: 67 in (170.2 cm)
  • Width: 52 in (132.1 cm)
Weight 550 lbs (250 kg)

cobas e 411 Analyzer

View Full Table

cobas e 411 Analyzer

 

System Fully automated, immunoassay analyzer for random access processing of ECL-based immunoassays (cobas e system format)
System components Self contained bench top analyzer comprising an analytical unit and a customized user interface
Types of modules
  • cobas e 411 disk analyzer
  • cobas e 411 rack analyzer
  • Optional System Table (cabinet); Optional System Table Extension (for printer)
System interfaces RS232 serial interface, bidirectional
Throughput Up to 86 tests/hour
Number of reagent channels 18 channels (reagent slots) for maximum of 18 tests
Programmable test parameters N/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database
Sample materials Serum/plasma, urine, others
Sample input/output
  • 30 positions for samples, calibrators and controls
  • 15 racks with 5 samples each (= 75 samples in/out)
Sample volume 10 - 50 μl.
Sample clot detection Standard (pressure sensor)
Sample barcode types Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39
Control unit Microsoft® Windows® XP-based panel PC
Calibrator/QC input cobas e system-specific barcoded CalSet vials on disk or racks
Calibration methods Lot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal)
QC methods
  • Individual QC and cumulative QC
  • Up to 100 controls pre-programmable
Data storage capacity The memory contains data files necessary for the analyzer and software to work together:
  • Reagent Data File: Up to 300 reagent packs
  • Sample Data File: Up to 2000 test records (for samples and controls)
  • Calibration Data File: Up to 160 calibrators - QC Data File: Capacity up to 100 controls
  • Operating Parameter Data File: Up to 305 reagent applications
  • Up to 20 operator IDs
Electrical requirements
  • 230/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack)
  • Frequency: 50 Hz or 60 Hz +/- 0.5%
Water/Waste requirements
  • Water: Bacteria free, de-ionized water supply, resistance of less than 10 μS/cm
  • Liquid waste: Onboard waste container (4 liter), direct drain optional
Operating conditions
  • Ambient temperature: 18 to 32°C
  • Ambient humidity: 20 to 80% RH (without condensation)
  • Heat Output: 2,879 kJ/hr (analyzer unit)
  • Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.)
Physical dimensions
  • Width (disk/rack): 120 cm / 170 cm 47.2 in / 67 in
  • Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in
  • Height: 80 cm / 31.4 in (closed top cover) 109 cm / 43 in (opened top cover)
Weight
  • Disk: 180 kg / 397 lbs
  • Rack: 250 kg / 551 lbs
Assay Menu

Assay Menu

cobas® analyzer series clinical chemistry assay menu
cobas® analyzer series immunoassay menu
Back     Next
error errorMessage
Sorry, we couldn't find the content you are looking for
Please try again later