For in vitro diagnostic use. Others cobas SARS-CoV-2 Liat IVD cobas® SARS-CoV-2 RMD-Liat-SARS-003 Nucleic acid test for use on the cobas® liat system 09 408 592 190 9 408 592 190 09408592190 9408592190 09408592190 KIT COBAS LIAT SARS-COV-2 cobas SARS-CoV-2 00875197006742 Reagents, kits 1 pack 20 tests true The cobas® SARS-CoV-2 Nucleic acid test for use on the cobas® Liat® System (cobas® SARS-CoV-2) is an automated, real- time reverse transcriptase polymerase chain reaction (RT-PCR) test intended for the rapid in vitro qualitative detection of nucleic acid from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in anterior nasal (nasal) and nasopharyngeal swab specimens collected from individuals with signs and symptoms of respiratory tract infection (i.e., symptomatic). Additionally, this test is intended to be used with nasal and nasopharyngeal swab specimens collected from individuals without signs and symptoms suspected of COVID-19 (i.e., asymptomatic).
The cobas® SARS-CoV-2 performed on the cobas® Liat® System is intended for use as an aid in the diagnosis of COVID-19 if used in conjunction with other clinical, epidemiologic, and laboratory findings. SARS-CoV-2 RNA is generally detectable in nasal and nasopharyngeal swab specimens during the acute phase of infection.
Positive results are indicative of the presence of SARS-CoV-2 RNA. Positive results do not rule out co-infection with other microorganisms.
A negative result from an asymptomatic individual is presumptive. Additionally, a negative result obtained with a nasal swab collected from an asymptomatic patient should be followed up by testing at least twice over three days with at least 48 hours between tests. Negative results do not preclude SARS-CoV-2 infection.
The results of this test should not be used as the sole basis for diagnosis, treatment, or other patient management decisions.
This test is intended for prescription use only and can be used in Point-of-Care settings. en The cobas® SARS-CoV-2 Nucleic acid test for use on the cobas® Liat® System (cobas® SARS-CoV-2) is an automated real-time RT-PCR assay intended for the rapid in vitro qualitative detection of SARS-CoV-2 in self-collected nasal swabs (collected in a healthcare setting with instruction by a healthcare provider) and healthcare provider-collected nasopharyngeal and nasal swabs from either individuals suspected of respiratory viral infection consistent with COVID-19 by their healthcare provider or from individuals without symptoms or other reasons to suspect COVID-19.
cobas® SARS-CoV-2 is intended for use in the detection of SARS-CoV-2 in clinical specimens. SARS-CoV-2 viral RNA is generally detectable in upper respiratory specimens during the acute phase of infection. Positive results are indicative of active infection but do not rule out co-infection with other pathogens not detected by the test. Clinical correlation with patient history and other diagnostic information is necessary to determine patient infection status. The agent detected may not be the definite cause of disease.
Negative results do not preclude infection from SARS-CoV-2 and should not be used as the sole basis for diagnosis, treatment or other patient management decisions. Negative results must be combined with clinical observations, patient history, and/or epidemiological information.
cobas® SARS-CoV-2 is intended for use by health professionals or trained operators who are proficient in using the cobas® Liat® System in Near Patient Testing, Point of Care (POC) or in a clinical laboratory setting. en The cobas® SARS-CoV-2 Nucleic acid test for use on the cobas® Liat® System (cobas® SARS-CoV-2) is an automated real-time RT-PCR assay intended for the rapid in vitro qualitative detection of SARS-CoV-2 in self-collected nasal swabs (collected in a healthcare setting with instruction by a healthcare provider) and healthcare provider-collected nasopharyngeal and nasal swabs from individuals suspected of respiratory viral infection consistent with COVID-19 by their healthcare provider.
cobas® SARS-CoV-2 is intended for use in the detection of SARS-CoV-2 in clinical specimens. SARS-CoV-2 viral RNA is generally detectable in upper respiratory specimens during theacute phase of infection. Positive results are indicative of active infection but do not rule out co-infection with other pathogens not detected by the test. Clinical correlation with patient history and other diagnostic information is necessary to determine patient infection status. The agent detected may not be the definite cause of disease.
Negative results do not preclude infection from SARS-CoV-2 and should not be used as the sole basis for diagnosis, treatment or other patient management decisions. Negative results must be combined with clinical observations, patient history, and/or epidemiological information.
cobas® SARS-CoV-2 is intended for use by health professionals or trained operators who are proficient in using the cobas® Liat® System in Near Patient Testing, Point of Care (POC) or in a clinical laboratory setting. en The cobas® SARS-CoV-2 assay is performed on the cobas® Liat® Analyzer which automates and integrates sample purification, nucleic acid amplification, and detection of the target sequence in biological samples using real-time RT-PCR assays. The assay targets both the ORF1 a/b non-structural region and structural nucleocapsid protein (N) gene that are unique to SARS-CoV-2. An Internal Process Control (IPC) is also included. The IPC is present to control for adequate processing of the target virus through steps of sample purification, nucleic acid amplification, and to monitor the presence of inhibitors in the RT-PCR processes. en
Zugriff auf die in Ihrem Land verfügbaren Dokumente
Sie befinden sich derzeit auf der globalen Website. Ändern Sie den Standort, um die lokalen Optionen zu sehen, oder greifen Sie auf eLabDoc zu — den Speicher für Produktdokumente.