Cell Marque - Instructions for UseCell Marque - Safety Data Sheet For in vitro diagnostic use. Membrane Others CD138 Syndecan-1 B-A38 IVD Plasmacytoma Tonsil CD138/syndecan-1 (B-A38) Mouse Monoclonal Antibody RTD000717 Mouse B-A38 05269083001 CD-138 (B-A38) PAb, Cell Marque CD138/syndecan-1 (B-A38) 00841683100478 Reagents, kits 50 tests Not Available true Le CD138/syndecan-1 (B-A38) Mouse Monoclonal Primary Antibody est destiné à un usage en laboratoire pour détecter la protéine CD138/syndecan-1 dans les tissus humains fixés au formol et enrobés à la paraffine, colorés par immunohistochimie (IHC) qualitative sur les instruments BenchMark IHC/ISH. Ce produit doit être interprété par un pathologiste compétent en parallèle avec un examen histologique, les informations cliniques pertinentes et les contrôles appropriés. Cet anticorps est destiné à être utilisé aux fins de diagnostic in vitro (IVD). fr CD138/syndecan-1 (B-A38) Mouse Monoclonal Antibody (this antibody) may be used as the primary antibody for immunohistochemical staining of formalin-fixed, paraffin-embedded tissue sections. In general, immunohistochemical staining allows the visualization of antigens via the sequential application of a specific antibody (primary antibody) to the antigen, a secondary antibody (link antibody) to the primary antibody, an enzyme complex and a chromogenic substrate with interposed washing steps. The enzymatic activation of the chromogen results in a visible reaction product at the antigen site. The specimen may then be counterstained and a coverslip applied. Results are interpreted using a light microscope and aid in the differential diagnosis of pathophysiological processes, which may or may not be associated with a particular antigen.This antibody is optimally diluted to be compatible with VENTANA detection kits and BenchMark IHC/ISH instruments. Refer to the Tables in the Instructions for Use section for recommended staining protocols. Each step in the staining protocol includes incubation for a precise time at a specific temperature. At the end of each incubation step, the sections are rinsed by the BenchMark IHC/ISH instruments to stop the reaction and remove unbound material that would hinder the desired reaction in subsequent steps. To minimize evaporation of the aqueous reagents from the specimen-containing slide, a coverslip solution is applied in the slide stainer. For more detailed information on instrument operation, refer to the appropriate BenchMark IHC/ISH instruments Operator’s Manual. en
Vous êtes actuellement sur le site Web mondial. Modifiez la localisation pour afficher les options de langues ou accédez à eLabDoc, le référentiel des documents des produits.