{ "ProductData": { "ID": "SYS_249", "ProductType": "System", "BrandName": "cobas® 8100 automated workflow series", "ProductNameAddition": "", "RegulatoryDisclaimer1": "For in vitro diagnostic use.", "DisclaimerGroup1": "IVD", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "cobas 8100 automated workflow series" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/qcobas-8100.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Analyzer Instruments and Systems", "NodeID": "10-000-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "cobas", "NodeID": "110" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Core Lab", "NodeID": "050-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Lab automation", "NodeID": "130" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "999-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "07123876001", "MaterialDescription": "cobas 8100 RSF (Restopper Flex-caps)", "RegisteredProductName": "cobas 8100 RSF (Restopper Flex-caps)", "GTIN": "04015630943753", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08010595001", "MaterialDescription": "cobas 8100 2nd BCL (BCL and modi kit)", "RegisteredProductName": "cobas 8100 BCL and modi kit", "GTIN": "07613336142561", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07439954001", "MaterialDescription": "c8100 v2 BRF incl. Conn.", "RegisteredProductName": "c8100 v2 BRF incl. Conn.", "GTIN": "04015630943838", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08015589001", "MaterialDescription": "cobas 8100 RSS (Restopper Screw Cap)", "RegisteredProductName": "cobas 8100 Restopper Screw Cap", "GTIN": "07613336142547", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123868001", "MaterialDescription": "cobas 8100 ACU", "RegisteredProductName": "cobas 8100 ACU", "GTIN": "04015630943746", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "08015597001", "MaterialDescription": "cobas 8100 2nd IPB (Input Buffer)", "RegisteredProductName": "cobas 8100 2nd Input Buffer", "GTIN": "07613336142554", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07439822001", "MaterialDescription": "c8100 v2 Type Alpha (IPB,DSP,OBS,CRW,CU)", "RegisteredProductName": "c8100 v2 Alpha (IPB,DSP,OBS,CRW,CU)", "GTIN": "04015630943364", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07439920001", "MaterialDescription": "c8100v2 Beta(IPB,DSP,BCL,AQM,OBS,CRW,CU)", "RegisteredProductName": "c8100 v2 Beta (IPB,DSP,BCL,AQM,OBS,CRW,CU)", "GTIN": "04015630943371", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123892001", "MaterialDescription": "cobas 8100 OBS (Output Buffer/Sorter)", "RegisteredProductName": "cobas 8100 OBS (Output Buffer/Sorter)", "GTIN": "04015630943760", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07440073001", "MaterialDescription": "c8100 v2 SCM", "RegisteredProductName": "c8100 v2 SCM", "GTIN": "04015630943906", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123922001", "MaterialDescription": "c 8100 BCL (Barcode Labeler/Tube Feeder)", "RegisteredProductName": "cobas 8100 BCL (Barcode Labeler/Tube Feeder)", "GTIN": "04015630943791", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07123914001", "MaterialDescription": "cobas 8100 AOB", "RegisteredProductName": "cobas 8100 AOB", "GTIN": "04015630943777", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" }, { "MaterialNum": "07787146001", "MaterialDescription": "cobas 8100 DSP (Destopper)", "RegisteredProductName": "cobas 8100 Destopper", "GTIN": "07613336101537", "ProductCategoryText": "Instruments", "OldMaterialNumber": "", "PackSizePIM360": "Not Available", "PackSizeDescPIM360": "Not Available", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "fr", "Value": "Le cobas® 8100 automated workflow series est un système automatisé, contrôlé par logiciel, de traitement d'échantillons patient avant leur analyse. Le système permet de centrifuger des échantillons patient, d'ôter et d'insérer des bouchons de tube échantillon le cas échéant, de mettre des étiquettes code-barres sur des tubes secondaires et de préparer des aliquotes à partir d'échantillons primaires. Il peut trier les échantillons pour une analyse en ligne ou hors ligne et peut stocker temporairement des échantillons. Le système transporte des échantillons individuels entre les modules et vers les analyseurs connectés.", "Country": "XG", "Code": "Intended Use", "Name": "Intended Use" } ] } } ] }

cobas® 8100 automated workflow series

Solutions 3D pour l’automatisation du laboratoire

Image produit de la gamme de solutions d’automatisation des flux de travail cobas® 8100
Avez-vous des questions ?
Nous contacter
Qualité et fiabilité

Le système de transport de tubes intelligent cobas 8100 fournit un délai d’obtention des résultats court et prédictible, avec la possibilité de prioriser les échantillons urgents. Avec un flux de travail flexible, la détection précoce des erreurs et une gestion des tubes entièrement automatisée, le cobas 8100 permet des solutions personnalisées pour s’adapter aux besoins des laboratoires tout en garantissant avant tout la qualité.

Charges de travail élevées et/ou délais d’exécution courts : la gamme de solutions d’automatisation des flux de travail cobas® 8100 s’adapte à vos objectifs de production et vous permet de travailler plus rapidement et plus efficacement.

Gamme de solutions d’automatisation des flux de travail cobas 8100

Charges de travail élevées et/ou délais d’exécution courts : la gamme de solutions d’automatisation des flux de travail cobas® 8100 s’adapte à vos objectifs de production et vous permet de travailler plus rapidement et plus efficacement.

La qualité avant tout

L’automatisation des étapes pré-analytiques permet une inspection approfondie des échantillons pour une efficacité maximale des flux de travail :

  • Vérification de la qualité des échantillons grâce à une caméra optique de haute résolution qui permet d’évaluer l’aspect du prélèvement (normal, limpide, hémolysé, ictérique)
  • Identification du type de tube
  • détection du niveau de liquide au laser
Adaptez votre flux de travail

La personnalisation des flux de travail vous permet de choisir entre un flux de travail de l’échantillon primaire, de l’aliquot ou mixte :

  • Flux de travail de l’échantillon primaire : lorsque l’accent est mis sur le rapport coût-efficacité
  • Flux de travail pour les aliquots : pour privilégier l’intégrité de l’échantillon et la réalisation de tests en parallèle
  • Flux de travail mixte : pour bénéficier des avantages des deux flux de travail
Des délais de traitement courts et prévisibles
  • Le système de transport d’échantillons permet aux laboratoires d’améliorer les soins aux patients en offrant des résultats fiables avec des délais d’exécution courts et prévisibles, même pendant les périodes de pointe.
  • Transport des tubes multi-niveaux et bi-directionnel : les supports de tubes vides et les supports contenant des tubes sont traités séparément pour éviter les engorgements.
  • Le système détermine le trajet optimal du tube et garantit un traitement des échantillons conforme à la méthode du « premier arrivé, premier servi ».
  • Les tubes peuvent contourner les modules lorsque le traitement n’est pas nécessaire.
  • Traitement en priorité des demandes urgentes (STAT)
Stockage flexible des tubes

Une solution avec le cobas® 8100 utilise 3 zones de stockage pour assurer un accès rapide au tube. 

  • Le stockage à très court terme permet d’effectuer une réanalyse immédiate
  • Le stockage à moyen terme, sur la journée, dans des modules AOB (Add-on Buffer), pour une exécution optimisée de demandes supplémentaires le jour même (add-on)
  • Stockage à long terme
Consolidation maximale
  • Large gamme de réactifs pour couvrir 98 % ou plus des examens habituels réalisés dans la ligne sérum.
  • Conçus pour consolider les activités de chimie clinique, d’immunologie, d’hématologie, de coagulation, les analyseurs tiers et les systèmes d’archivage sélectifs
  • Le système cobas® 8100 automatise entièrement les flux de travail des laboratoires, de la prise en charge des échantillons à leur archivage
  • Des solutions post-analytiques intégrées avec des modules Add-on Buffer pour les demandes supplémentaires au cours de la même journée
Solutions 3D pour l’automatisation du laboratoire

Le cobas® 8100 délivre un flux de travail flexible, totalement automatisé avec une détection précoce des erreurs. Cette solution intelligente vous permet d’utiliser votre laboratoire de manière optimale et garantit la qualité de l’échantillon.

Aperçu

Commander

Retour     En avant
error errorMessage
Un problème est survenu lors du chargement de cette section.
Veuillez recharger cette page ou réessayer plus tard.